IMPORTANT SAFEGUARDS AND WARNINGS

HEATITCABLE.COM

3

Important safeguards and warnings

• Please read the Instruction Manual and keep it properly before installing and using the product.

• The electric pump must be reliably grounded before use, and leakage protection devices should be installed.

• It is forbidden to touch the electric pump during operation.

• Dry running of the electric pump is strictly prohibited.

• It is strictly prohibited for children, and persons with no capacity or limited capacity to use the product without supervision 

  of guardians (such as not being taught the safe use method of the product and understanding the risks involved).

• The pump system must be able to withstand the maximum pump pressure.

• The manufacturer shall not be held responsible for any consequences caused by the user modifying the electric pump 

  without authorization or operating the electric pump beyond the operating conditions.

Thank you very much for choosing our products. Please read the Instruction Manual carefully and keep it 

properly before installation and use.

GENERAL INSTALLATION INSTRUCTIONS

The product is installed in the backwater pipeline of the water heater. 

Conveying liquid

The conveying liquid is softened water and thin, clean, non-corrosive, non-explosive liquid without solid particles, fibers 

and mineral oil, and the PH value of the medium is between 6.5 and 8.5.
The requirements for the operation system of the electric pump are shown in the following figure 2 :

Medium and ambient temperature

The system temperature (t1) must be always higher than the ambient temperature (t2) in order to avoid electrical short 

circuit of junction box caused by condensation of pump body(see figure 3). 

Maximum pressure borne by electric 

pump 145 PSI

If the pressure difference between hot and 

cold water pipes is greater than 1.45 PSI,

the backwater device may not return water 

normally, thus affecting the use effect.

Min. liquid temperature·····35.6

Max. liquid temperature···158 

 

    System temperature (t1)

Ambient temperature (t2)

Min. ambient temperature····35.6

Max. ambient temperature····104

figure 2

figure 3

Содержание HIP 24-12A

Страница 1: ...SMART INSTANT HOT WATER RECIRCULATING SYSTEM HEATITCABLE COM HIP 24 12A ...

Страница 2: ...ing The pump head is made of lead free grade copper material durable and rust free protecting the health of your whole family Easy to install with the necessary accessories included 10 power cord Built in thermostat Maintenance free Can be used with all types of pipe Three modes can be chosen energy saving mode smart mode and manual mode When the water temperature in the pump is lower than 33 the ...

Страница 3: ...choosing our products Please read the Instruction Manual carefully and keep it properly before installation and use GENERAL INSTALLATION INSTRUCTIONS The product is installed in the backwater pipeline of the water heater Conveying liquid The conveying liquid is softened water and thin clean non corrosive non explosive liquid without solid particles fibers and mineral oil and the PH value of the me...

Страница 4: ...t used for a long time or no one is at home please close the water pipe valve at the inlet and outlet end and cut off the power supply of the recirculating pump 7 Cable or power adapter when damaged must be replaced 8 In winter when the ambient temperature is lower than 0 C if the electric pump stops running the water in the pipeline system must be drained to prevent the pump from freezing and cra...

Страница 5: ...r to open the valve of cold water pipe hot water pipe return pipe after installation DO NOT Mount Motor Shaft in Vertical Position Commissioning Panel description Function description Mold name Mold description Smart constant temperature mode Energy saving constant temperature mode Manual mode When turned on the icon lights orange and the pump operates at constant temperature throughout a day When...

Страница 6: ...r at the electric pump Power on again after cutting off the power for 10 seconds If the red light blinks remove the circulation pump and sent it back to the manufacturer for repair Check whether the check valve is blocked or installed Check whether there are any valves that are not open Remove the pump body and remove sundries Switch to low gear operation or turn down the outlet valve appropriatel...

Отзывы: