background image

GENERAL INSTALLATION INSTRUCTIONS

1. Before installing the pump, check whether the pipeline system is connected reliably and ensure that impurities, welding 

    slag,   dirt and the like in the pipeline have been removed.   The output of the voltage adapter is  low-voltage  DC 24V. 

    During installation,  a filtering screen can be installed at the inlet of the recirculating pump to filter large particles and 

    impurities in the water, and the filter screen shall be cleaned regularly. It depends on the pipe water situation. You can 

    choose to install or not. If the water in the pipe is always clean, you don’t need to install this screen. 

2. The HIP24-12A pump must be installed or maintained by a professional plumber . Install the pump according to the 

    installation diagram of the HIP24-12A pump. Pay attention to the water pipe connection between the water inlet and 

    the water outlet. After installation, check the HIP24-12A pump and all water pipe fittings for water leakage

.

 The 

    HIP24-12A pump shall be prevented from being splashed by water to avoid electric shock. 

3. After connecting the power adapter, conduct a test run of the recirculating pump to check whether the startup is normal, 

    but the nonwater running time should not exceed 5 seconds to prevent the operation from reducing the bearing life. 

4. When the HIP24-12A pump works, if you want to adjust the position of or touch the recirculating pump,the power supply 

    must be the first cut off to prevent accidents.

5. Carry out regular inspection and make replacement in time when damage occurs.

6. If the HIP24-12A pump is not used for a long time or no one is at home, please close the water pipe valve at the inlet 

    and outlet end and cut off the power supply of the recirculating pump.

7. Cable or power adapter, when damaged, must be replaced.

8. In winter, when the ambient temperature is lower than 0°C, if the electric pump stops running, the water in the pipeline 

      system must be drained to prevent the pump from freezing and cracking.

Installation tips

Installation steps 

1.  For  Electric Water Heater : Turn off Power to your Water Heater.  ( turn off power at breaker box ).  For Gas Water 

     Heater : Turn off the gas to your water heater and ensure that the pilot light is not burning. Shut off the supply water 

     valve to the water heater. In most cases, the supply water valve located above the hot water heater on the cold water 

     inlet to the hot water heater. 

2.  Drain the water from the backwater pipe by opening a cold water faucet in the house. Let the water run until it stops 

     flowing. Then drain remaining water from hot water heater spigot. Leave the faucet open until the pump installation is 

     complete. If water does not stop flowing, check to make sure the water to the hot water heater has been completely 

     shut off. 

3.  Disconnect the backwater pipe with the water heater. 

  3.2 (optional)Find a suitable installation position (on the back water pipe near the water heater end). When installing 

        the water pump support plate in advance, the support plate can be placed in the pre-installation position and marked 

        with a marker at the installation hole. The drilling size is φ6.

HEATITCABLE.COM

4

3.3 Insert the plastic expansion screw into the hole drilled in the wall. 

3.4 Fix the support plate on the wall with self-tapping screws.

3.5 Clip the pump onto the hook of the support plate indicated by the arrow.

Содержание HIP 24-12A

Страница 1: ...SMART INSTANT HOT WATER RECIRCULATING SYSTEM HEATITCABLE COM HIP 24 12A ...

Страница 2: ...ing The pump head is made of lead free grade copper material durable and rust free protecting the health of your whole family Easy to install with the necessary accessories included 10 power cord Built in thermostat Maintenance free Can be used with all types of pipe Three modes can be chosen energy saving mode smart mode and manual mode When the water temperature in the pump is lower than 33 the ...

Страница 3: ...choosing our products Please read the Instruction Manual carefully and keep it properly before installation and use GENERAL INSTALLATION INSTRUCTIONS The product is installed in the backwater pipeline of the water heater Conveying liquid The conveying liquid is softened water and thin clean non corrosive non explosive liquid without solid particles fibers and mineral oil and the PH value of the me...

Страница 4: ...t used for a long time or no one is at home please close the water pipe valve at the inlet and outlet end and cut off the power supply of the recirculating pump 7 Cable or power adapter when damaged must be replaced 8 In winter when the ambient temperature is lower than 0 C if the electric pump stops running the water in the pipeline system must be drained to prevent the pump from freezing and cra...

Страница 5: ...r to open the valve of cold water pipe hot water pipe return pipe after installation DO NOT Mount Motor Shaft in Vertical Position Commissioning Panel description Function description Mold name Mold description Smart constant temperature mode Energy saving constant temperature mode Manual mode When turned on the icon lights orange and the pump operates at constant temperature throughout a day When...

Страница 6: ...r at the electric pump Power on again after cutting off the power for 10 seconds If the red light blinks remove the circulation pump and sent it back to the manufacturer for repair Check whether the check valve is blocked or installed Check whether there are any valves that are not open Remove the pump body and remove sundries Switch to low gear operation or turn down the outlet valve appropriatel...

Отзывы: