HEATIT Smart Instant Hot Water Recirculating System help you to save gallons of water in waiting for water warm up
each year. Up to 10% of your water bill will be saved. You can get the instant hot water when you need it. No more
water wasted in waiting. HEATIT smart pumps bring you convenience and savings.
HEATIT HIP 24-12A smart pump was designed to be installed on the back water pipe to the water heater (see the
picture 1). If there is no back water pipe to water heater in your water loop, you may need HEATIT HIP 24-12B to be
installed under the faucet furthest from the water heater in each loop.
Product Overview
Hot water pipe
Backwater pipe
Cold water pipe
Product Features
• HEATIT HIP smart hot water recirculating pump adopts a plastic-sealed permanent magnet synchronous motor with
ultra-low safe voltage (24V). The shell is made of die-cast aluminum with high strength and anti-aging. The pump head
is made of lead free grade copper material, durable and rust-free, protecting the health of your whole family.
• Easy to install with the necessary accessories included. 10' power cord. Built in thermostat. Maintenance free. Can be
used with all types of pipe.
• Three modes can be chosen: energy-saving mode, smart mode and manual mode. When the water temperature in the
pump is lower than 33
℃
, the pump will push the cold water back to the water heater. As the temperature hits 38
℃
,
the pump will stop working.
• Advanced motor technology: Permanent magnet brush less motor DC motor makes the pump more powerful, more
quiet and more durable. (Max flow 6 GPM, Max head 39.3ft)
Package Contents
Package Contains the following:
• Smart Hot water recirculator pump with build-in thermostat
• Hook: 2x
• Self-tapping screws: 2x ST3.5x9.5
• Expansion screw: 2x M6×30
• Power adapter: 1x 24V/3A
• Installation and Operating Instructions
• Filter(optional)
picture 1
Inlet of pump
Outlet
of
pump