Heatilator • RAVE4013I-D • 2328-900 Rev. F • 9/17
28
Figure 7.7
1. Top Vent - Horizontal Termination
- (continued)
Top Vent - Horizontal Termination
Venting with 3 elbows
Note
: Use SLP Series
components only.
V Minimum
H
1
+ H
2
+ H
3
MAXIMUM
RAVE4013I-D (NG ONLY)
3 ft.
914 mm
15 ft.
4.6 m
H
1
+ H
2
+ H
3
MAX. = 15 ft. (4.6 m)
V
1
MAX. = 7 ft (2.1 m)
V
1
H
1
H
3
H
2
INSTALLED
HORIZONTALLY
INSTALLED
HORIZONTALLY
Note
: There MUST be a 25%
reduction in total H when using
flex vent except when using the
simple up and out installation
(see Figure 7.17).
CAUTION:
The SLP-HRC-SS termination cap is not
approved for use with propane (LP) fuel.
May lead
to elevated glass temperature that may cause tem
-
pered glass breakage.