Heatilator • RAVE4013I-D • 2328-900 Rev. F • 9/17
20
D. Mantel and Wall Projections
WARNING!
Risk of Fire!
Comply with all minimum clear-
ances to combustibles as specified. Framing or finishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Figure 5.3 Clearances To Combustible Mantels Or Other
Combustibles Above Appliance
Figure 5.4 Clearances To Non-Combustible Mantels Or Other
Non-Combustibles Above Appliance
Combustible Mantels
Non-combustible Mantels
3 FT. MAXIMUM
6 IN.
MINIMUM
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 16.1).
7 IN.
MINIMUM
UNLIMITED
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 16.1).
14 IN.
MIN.
12 IN.
MAX.
1/2 IN.
Thick Wall
Sheathing
MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING
See Dimension T on Appliance
Dimension Diagram (Figure 16.1).
Note:
For non-combustible fireplace finish material (marble,
stone, etc) specifications refer to Section 13.C.
14 IN.
MIN.
12 IN.
MAX.
1/2 IN.
Thick Wall
Sheathing
4 IN.
MAX.
1 IN.MIN.
MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING
See Dimension T on
Appliance Dimension
Diagram (Figure 16.1).
Figure 5.7 Front Side Finishing Detail
1 IN.
FRAMING
1/2 IN. FACTORY-SUPPLIED
NON-COMBUSTIBLE BOARD
NAILING TAB
Figure 5.5 Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Figure 5.6 Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Note
: Clearance from opening
to perpendicular wall.
Note
: Clearance from opening
to perpendicular wall.
Mantel Legs Or Wall Projections Extending Past The Face
Of The Fireplace (Combustible or Non-Combustible)