27
Heatilator • RAVE4013I-D • 2328-900 Rev. F • 9/17
H
2
H
1
V
2
V
1
Top Vent - Horizontal Termination
Venting with 3 elbows
Note
: Use SLP Series
components only.
1. Top Vent - Horizontal Termination
- (continued)
Figure 7.6
RAVE4013I-D
V
1
Minimum
H
1
+ H
2
Maximum
V
2
V
1
+ V
2
Minimum
90° Elbow
6 ft.
1.8 m
*
*
1 ft.
305 mm
10 ft.
3.0 m
*
*
2 ft.
610 mm
12 ft.
3.7 m
*
*
3 ft.
914 mm
14 ft.
4.3 m
*
*
H
1
+ H
2
MAX. =14 ft. (4.3 m)
V
1
+ V
2
+ H
1
+ H
2
MAX. = 40 ft. (12.2 m)
*No specific restrictions on this value EXCEPT V
1
+ V
2
+ H
1
+ H
2
cannot exceed 40 ft. (12.2 m)
Note
: There MUST be a 25%
reduction in total H when using
flex vent except when using the
simple up and out installation
(see Figure 7.17).
CAUTION:
The SLP-HRC-SS termination cap is not
approved for use with propane (LP) fuel.
May lead
to elevated glass temperature that may cause tem
-
pered glass breakage.