25
Heatilator • RAVE4013I-D • 2328-900 Rev. F • 9/17
Figure 7.4
Top Vent - Horizontal Termination
Venting with 1 elbow
H
1
V
1
V Minimum
H
1
Maximum
RAVE4013I-D
90 Elbow
1-1/2 ft.
457mm
1 ft.
305 mm
3 ft.
914 mm
2 ft.
610 mm
5 ft.
1.5 m
3 ft.
914 mm
7 ft.
2.1 m
4 ft.
1.2 m
14 ft.
4.3 m
H MAX. =14 ft. (4.3 m)
V + H MAX. = 40 ft. (12.2 m)
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling firestops.
• ALWAYS maintain specified clearances around venting and firestop systems.
• Install wall shield and ceiling firestops as specified.
Failure to keep insulation or other material away from vent pipe may cause fire.
WARNING
Note
: Use SLP Series
components only.
Note
: There MUST be a 25%
reduction in total H when using
flex vent except when using the
simple up and out installation
(see Figure 7.17).
CAUTION:
The SLP-HRC-SS termination cap is not
approved for use with propane (LP) fuel.
May lead
to elevated glass temperature that may cause tem
-
pered glass breakage.