6
35048 Rev L
03/04
IB75 B-VENT GAS APPLIANCE
Figure 3 shows typical framing of this appliance using combustible materials and the minimum mantel heights. All required
clearances to combustibles must be adhered to. Figure 4 shows rough framing dimensions.
This appliance may be placed on a smooth combustible or noncombustible continuous, flat surface. When the appliance
is installed directly on carpeting, tile, or a combustible material other than wood flooring, the appliance shall be installed
on a metal or wood panel extending the full width and depth of the appliance. Slide the appliance into position and level
the appliance from side-to-side and front-to-back. Shim with noncombustible material as necessary.
Secure the appliance by bending out the nailing flanges on each side of the appliance and nail to framing. The nailing
flanges have been positioned 1/2 in. back from the front of the appliance to allow the addition of drywall.
WARNING!
This appliance may only use an approved B-Vent chimney system. It must not be connected to a chimney flue
servicing a separate solid fuel or gas fuel burning appliance.
Figure 3 - Framing
CAUTION:
Wear gloves and safety glasses for protection.
CAUTION:
Provide adequate clearances around the air
openings into the combustion chamber and
adequate accessibility clearances for servicing and
proper operation.
C. FRAMING
D. SETTING THE APPLIANCE
Figure 4 - Rough Framing Dimensions
WARNING!
To prevent contact with sagging or loose insulation, the appliance must not be installed against vapor barriers
or exposed insulation.