03/04
35048 Rev L
11
IB75 B-VENT GAS APPLIANCE
Note:
This appliance must be electrically wired and
grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the
Canadian Electric
Code, CSA C22l.1
.
Figure 12 - Intermittent Pilot Ignition Wiring Diagram
CAUTION:
Battery polarity must be correct or control module
damage will occur.
5.
b. Ignition System
This appliance is equipped with an intermittent pilot control valve which operates on a 3 volt system. See wiring
diagram, Figure 12.
The appliance is supplied with a battery pack and a 3 volt AC transformer, which requires the installation of the
supplied JK9 Junction Box Kit. It is highly recommended that the JK9 be installed at this time to avoid reconstruction.
The battery pack requires two D cell batteries (not included). Batteries cannot be placed in the battery pack while
using the 3 volt AC transformer. Conversely, the transformer must be unplugged if the battery pack is used.
6.Install the JK9 Junction Box
Your appliance is supplied with a JK9 Junction Box. To operate the appliance with the supplied 3VAC transformer
and/or remote control option, it is recommended that the junction box be installed and wired to the appliance at this
time to avoid reconstruction.
a.
Refer to installation instructions included with the JK9 Junction Box.
b.
Wire the junction box per the diagram in Figure 12.