01/04
35593 Rev G
21
CALIBER DESIGNER DIRECT VENT
Note:
This appliance must be electrically wired and
grounded in accordance with local codes or, in the
absence of local codes, with
National Electrical
Code ANSI/NFPA 70-latest edition
or the
Canadian
Electrical Code CSA C22.1
.
5. Wiring
Note:
Optional Accessories Requirements: Wiring
for optional accessories should be done now to avoid
reconstruction.
CAUTION:
Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after
servicing.
a. Standing Pilot Ignition
1) Appliance Requirements
This standing pilot appliance does not require
a 110V AC supply to operate. It is suggested
that a 110V junction box be installed with a
switched outlet for the optional electric ember
light kit and an always-powered outlet for the
optional remote control. See Figure 38 for
wiring diagram.
Figure 38 - Standing Pilot Ignition Wiring Diagram
WARNING!
This standing pilot appliance DOES NOT require a
110VAC supply for operation. Connecting the ap-
pliance wall switch wires to 110VAC supply will
cause the appliance to malfunction and destroy the
valve and thermopile.
2) Wall Switch Wiring
The installer shall supply a UL-listed or in Canada, a CSA-listed wall switch. This appliance was tested
with eighteen feet of UL listed 18 ga. Type CL2 105°C, two conductor thermostat wire. If other wiring
materials are used they shall comply with local codes. In the absence of local codes, they shall comply
with the
National Electrical Code ANSI/NFPA 70-latest edition or Canadian Electrical Code CSA
C22.1.