INSTALLATION

For easy installation, select an existing light with a wall
switch for replacement.

 

W

IRE

 

THE

 L

IGHT

 C

ONTROL

.

Turn power off at the fuse or circuit breaker.

Remove the existing light fixture.

Install the mounting strap as shown using two
screws that fit your junction box.

The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger can
be threaded through the hole in the center of the
cover plate. The small end then goes into one of the
slots on the mounting strap.

Route the Light Control’s wires through the large
gasket hole.

M

OUNT

 

THE

 L

IGHT

 C

ONTROL

.

Align the Light Control cover plate and cover plate

gasket. Secure with the mounting bolt.

Push the Rubber Plug firmly into place.

If a wet location junction box was not used, caulk the

wall plate mounting surface with silicone weather
sealant.

Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180

°

from the factory setting. When screwing in the
floodlamps, do not overtighten.

For eave mount only:

Swing the sensor head towards the clamp screw

joint.

If the sensor pops out of the ball joint, loosen the clamp
screw and push the sensor back into the ball joint.
Tighten the clamp screw when done.

Then rotate the sensor head clockwise 180

°

 so the

controls face down.

Wall Mount

Eave Mount

For under eave installation, the sensor head must
be rotated
 as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.

1234567890123456789

1234567890123456789

1234567890123456789

Controls

Clamp screw

Controls

Controls

Lock nut

To avoid water damage and
electrical shock, keep lamp
holders below horizontal.

Keep lamps at least
1" (2.5 cm) from the
sensor.  Do not al-
low the lamps to
block the lens.

Lens

 Twist the junction box wires and fixture wires  together

as shown. Secure with wire connectors.

White to
White

Black to
Black

Junction box ground wire to green
ground screw on fixture.

Gasket

Mounting

Strap

Mounting

Bolt

Rubber

Plug

Содержание CB-2010

Страница 1: ...t ON TIME switch on the sensor bottom to TEST MANUAL MODE ON TIME TEST 1 5 20 back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 20 minute position Move ON TIME Switch to 1 5 or 20 minutes Mode Switching Summary Flip light switch off for one second then back on MANUAL MODE AUTO TEST Note When first turned on wait about 12 minutes for the circuitry to calibrate Manual mode only wor...

Страница 2: ...g the lock nuts but do not rotate the lamp holders more than 180 from the factory setting When screwing in the floodlamps do not overtighten For eave mount only Swing the sensor head towards the clamp screw joint Ifthesensorpopsoutoftheballjoint loosentheclamp screw and push the sensor back into the ball joint Tighten the clamp screw when done Thenrotatethesensorheadclockwise180 sothe controls fac...

Страница 3: ...oting where you are whenthelightsturnon Move thesensorheadup down or sideways to change the cov eragearea Keepthesensor at least 1 2 5 cm away from the lamps Adjust the RANGE as needed RANGEsettoohigh mayincreasefalsetriggering Secure the sensor head s aimbytighteningtheclamp screw Do not overtighten the screw Clamp Screw Ball Joint Aim Sensor Down for Short Coverage Aim Sensor Higher for Long Cov...

Страница 4: ...en stay off in Manual Mode 1 Sensor is detecting its own lights Reposition lamps to keep area below the sensor relatively dark YOUR HEATH ZENITH 15 YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights which vary from state to state or province to province For a period of 15 years from the date of purchase any malfunction caused by fa...

Страница 5: ...ne al detector en modo AUTOMATICO Apague el interruptor por un segundo y vuélvalo a prender Elmodomanualfuncionasólocuando el interruptor de tiempo ON TIME estáenlaposiciónde1 5ó20minutos préndalo 1 segundo APAGADO luego Mueva el interruptor de tiempo ON TIME a 1 5 ó 20 minutos Apague el interruptor por un segundo y préndalo de nuevo ON TIME TEST 1 5 20 Ponga el control de tiempo ON TIME en la pos...

Страница 6: ...ornillo de montaje Empuje el tapón de caucho firmemente hasta que encaje Si no se usó una caja de empalme en un lugar húmedo calafatee la superficie de montaje de la placa de la pared con un sellador de silicona contra la intemperie Para instalarlo bajo el alero la cabeza del detector debe ser girada como se muestra en los dos pasos siguientes para evitar el riesgo de un choque eléctrico Gire la c...

Страница 7: ...ía con la temperatura del medio ambiente Angulo de detección Hasta 200 Carga Eléctrica 300 Vatios incandescente 150 cada portalámparas Requisitos de Energía 120 VCA 60 Hz Fases de Operación PRUEBA AUTOMATICO y MODO MANUAL Retardo de Tiempo 1 5 20 minutos Heath Zenithsereservaelderechodedescontinuarproductos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligación de ten...

Страница 8: ...El detector está detectando su propia luz Reubique las lámparas para mantener el área debajo del detector relativamente oscura SU GARANTÍA HEATH ZENITH LIMITADA A 15 AÑOS Esta es una Garantía Limitada que le da a Ud derechos legales específicos Usted puede también tener otros derechos que varían de estado a estado o de provincia a provincia Por un período de 15 años desde la fecha de compra cualqu...

Страница 9: ...rupteur de temps en circuit ON TIME à la position correspondant à 1 5 ou 20 minutes PRIORITÉ MANUELLE hors circuit pendant 1 seconde puis à nouveau en circuit Placer l interrupteur ON TIME à 1 5 ou 20 minutes Mettre l interrupteur hors circuit pendant une seconde puis le remettre en circuit Si vous ne savez plus dans quel mode se trouve l appareil couper l alimentation pendant une minute puis la r...

Страница 10: ...utilisée calfeutrer la surface de montage de la plaque murale avec un scellant silicone d extérieur Câblage de la Commande D Éclairage Couper l alimentation du circuit d éclairage au fusible ou au disjoncteur Enlever l appareil d éclairage existant Installer la bride de montage comme indiqué avec deux vis correspondant à votre boîte de jonction Le crochet en plastique peut peut servir à supporter ...

Страница 11: ...lacer la tête du détecteur vers le haut le bas ou le côté pour modifier la zone de couverture Ne paspermettreaudétecteur d être à moins de 25 mm des lampes Régler la sensibilité RANGE selon les besoins Une trop grande sensibilité pourrait causer des d é c l e n c h e m e n t s intempestifs Pour une couverture accrue utiliser l amplification de portée Range Boost Fixer la tête du détecteur en posit...

Страница 12: ... clignotent L éclairage clignote une fois puisreste éteint en mode manuel 1 Le capteur détecte son propre éclairage Repositionner les lampes pour que l aire sous le capteur demeure relativement sombre VOTRE GARANTIE LIMITÉE DE 15 ANS HEATH ZENITH Il s agit d une Garantie limitée qui vous confère des droits juridiques spécifiques Vous pouvez également jouir d autres droits variables d une province ...

Отзывы: