Motion

Motion

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE:

Sensor has a 1

2

 minute warm up period

before it will detect motion.  When first turned
on or when switching modes wait 1

2

 minutes.

Bottom of Sensor

Avoid aiming the sensor at:

Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

Areas where pets or traffic may trigger the con-

trol.

Nearby large, light-colored objects reflecting

light may trigger the shut-off feature. Do not point
other lights at the sensor.

Maximum Range

8 ft.

(2.4 m)

Maximum

Coverage Angle

70 ft.

100 ft.

(21 m) (30.5 m)

Boosted

Least Sensitive

      Most Sensitive

Sensor

The detector is less sensitive to motion directly
towards it.

Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.

Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cov-
erage area. Keep the sensor
at least 1" (2.5 cm) away
from the lamps
.

Adjust the RANGE as
needed.  RANGE set too high
may increase false triggering.

Secure the sensor head's
aim by tightening the clamp
screw.
 Do not overtighten
the screw.

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5 or 20 minutes).

SPECIFICATIONS

Range . . . . . . . . . . . .  Up  to  70  ft.  (21  m);  100  ft.

(30.5 m) with Range Boost.
[varies with surrounding
temperature]

Sensing Angle . . . . . .  Up to 200

°

Electrical Load . . . . . .  300 watt Incandescent [150 W

each lamp holder].

Power Requirements .  120 VAC, 60 Hz
Operating Modes . . . .  TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . .  1 , 5, 20 minutes

Heath/Zenith reserves the right to discontinue products and to
change specifications at any time without incurring any obligation
to incorporate new features in products previously sold.

200

°

Turn the RANGE control to the mid position and
the ON-TIME control to the TEST position.

Содержание CB-2010

Страница 1: ...t ON TIME switch on the sensor bottom to TEST MANUAL MODE ON TIME TEST 1 5 20 back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 20 minute position Move ON TIME Switch to 1 5 or 20 minutes Mode Switching Summary Flip light switch off for one second then back on MANUAL MODE AUTO TEST Note When first turned on wait about 12 minutes for the circuitry to calibrate Manual mode only wor...

Страница 2: ...g the lock nuts but do not rotate the lamp holders more than 180 from the factory setting When screwing in the floodlamps do not overtighten For eave mount only Swing the sensor head towards the clamp screw joint Ifthesensorpopsoutoftheballjoint loosentheclamp screw and push the sensor back into the ball joint Tighten the clamp screw when done Thenrotatethesensorheadclockwise180 sothe controls fac...

Страница 3: ...oting where you are whenthelightsturnon Move thesensorheadup down or sideways to change the cov eragearea Keepthesensor at least 1 2 5 cm away from the lamps Adjust the RANGE as needed RANGEsettoohigh mayincreasefalsetriggering Secure the sensor head s aimbytighteningtheclamp screw Do not overtighten the screw Clamp Screw Ball Joint Aim Sensor Down for Short Coverage Aim Sensor Higher for Long Cov...

Страница 4: ...en stay off in Manual Mode 1 Sensor is detecting its own lights Reposition lamps to keep area below the sensor relatively dark YOUR HEATH ZENITH 15 YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights which vary from state to state or province to province For a period of 15 years from the date of purchase any malfunction caused by fa...

Страница 5: ...ne al detector en modo AUTOMATICO Apague el interruptor por un segundo y vuélvalo a prender Elmodomanualfuncionasólocuando el interruptor de tiempo ON TIME estáenlaposiciónde1 5ó20minutos préndalo 1 segundo APAGADO luego Mueva el interruptor de tiempo ON TIME a 1 5 ó 20 minutos Apague el interruptor por un segundo y préndalo de nuevo ON TIME TEST 1 5 20 Ponga el control de tiempo ON TIME en la pos...

Страница 6: ...ornillo de montaje Empuje el tapón de caucho firmemente hasta que encaje Si no se usó una caja de empalme en un lugar húmedo calafatee la superficie de montaje de la placa de la pared con un sellador de silicona contra la intemperie Para instalarlo bajo el alero la cabeza del detector debe ser girada como se muestra en los dos pasos siguientes para evitar el riesgo de un choque eléctrico Gire la c...

Страница 7: ...ía con la temperatura del medio ambiente Angulo de detección Hasta 200 Carga Eléctrica 300 Vatios incandescente 150 cada portalámparas Requisitos de Energía 120 VCA 60 Hz Fases de Operación PRUEBA AUTOMATICO y MODO MANUAL Retardo de Tiempo 1 5 20 minutos Heath Zenithsereservaelderechodedescontinuarproductos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligación de ten...

Страница 8: ...El detector está detectando su propia luz Reubique las lámparas para mantener el área debajo del detector relativamente oscura SU GARANTÍA HEATH ZENITH LIMITADA A 15 AÑOS Esta es una Garantía Limitada que le da a Ud derechos legales específicos Usted puede también tener otros derechos que varían de estado a estado o de provincia a provincia Por un período de 15 años desde la fecha de compra cualqu...

Страница 9: ...rupteur de temps en circuit ON TIME à la position correspondant à 1 5 ou 20 minutes PRIORITÉ MANUELLE hors circuit pendant 1 seconde puis à nouveau en circuit Placer l interrupteur ON TIME à 1 5 ou 20 minutes Mettre l interrupteur hors circuit pendant une seconde puis le remettre en circuit Si vous ne savez plus dans quel mode se trouve l appareil couper l alimentation pendant une minute puis la r...

Страница 10: ...utilisée calfeutrer la surface de montage de la plaque murale avec un scellant silicone d extérieur Câblage de la Commande D Éclairage Couper l alimentation du circuit d éclairage au fusible ou au disjoncteur Enlever l appareil d éclairage existant Installer la bride de montage comme indiqué avec deux vis correspondant à votre boîte de jonction Le crochet en plastique peut peut servir à supporter ...

Страница 11: ...lacer la tête du détecteur vers le haut le bas ou le côté pour modifier la zone de couverture Ne paspermettreaudétecteur d être à moins de 25 mm des lampes Régler la sensibilité RANGE selon les besoins Une trop grande sensibilité pourrait causer des d é c l e n c h e m e n t s intempestifs Pour une couverture accrue utiliser l amplification de portée Range Boost Fixer la tête du détecteur en posit...

Страница 12: ... clignotent L éclairage clignote une fois puisreste éteint en mode manuel 1 Le capteur détecte son propre éclairage Repositionner les lampes pour que l aire sous le capteur demeure relativement sombre VOTRE GARANTIE LIMITÉE DE 15 ANS HEATH ZENITH Il s agit d une Garantie limitée qui vous confère des droits juridiques spécifiques Vous pouvez également jouir d autres droits variables d une province ...

Отзывы:

Похожие инструкции для CB-2010