When planning a fireplace installation, its necessary to determine:
Where the unit is to be installed.
The vent system configuration to be used.
Gas supply piping.
Electrical wiring.
Framing and finishing details.
Whether optional accessoriesdevices such as a fan, wall switch, or remote
controlare desired.
If the fireplace is to be installed on carpeting or tile, or on any combustible
material other than wood flooring, the fireplace should be installed on a metal or
wood panel that extends the full width and depth of the fireplace.
The CFK-SL36 Clean Face Kit is designed to convert a Model SL-36 Gas
Fireplace to a Clean Face Design. The kit includes a top extension piece, an
upper grille cover, and a lower grille cover. See Figure 2. The following
requirements
MUST
be met if this kit is installed.
IF THESE REQUIREMENTS
ARE NOT MET, A POTENTIAL FIRE HAZARD WILL EXIST AND THE
FIREPLACE WARRANTY WILL BE VOIDED.
1. The first vent component attached to the fireplace starting collar
MUST
be
a 3-foot (904 mm) length of straight pipe.
2. The top extension piece in this kit
MUST
be properly installed to avoid a fire
hazard.
3. The lower fireplace grille
MUST
be able to be opened for access to the gas
valve and controls. This condition
MUST
be met after the Clean Face Kit is
installed and the fireplace finishing has been completed.
4. An optional fan (kit no. GFK-160A or any other fan)
CANNOT
be installed in
the SL-36 fireplace when converted to a clean face fireplace.
5. Damaged components or components field-modified without factory autho-
rization cannot be installed or used. Installation instructions are included in
the CFK-SL36 Kit.
Содержание SL-32
Страница 8: ...5 Figure 1 Diagram of the SL 36 Circulating Version ...
Страница 9: ...6 Figure 2 Diagram of the SL 36 Clean face Version ...
Страница 10: ...7 Figure 3 Diagram of the SL 36GDV ...
Страница 11: ...8 Figure 4 Diagram of the SL 32S and SL 32 ...
Страница 12: ...9 Figure 5 Diagram of the SL 32GDV ...
Страница 19: ...16 STRAIGHTOUTHORIZONTAL VENTING H Max Run 36 914 mm Figure 12 Straight Out Horizontal Venting ...