20
V(FT.)
H (FT.)
1' MIN. (305mm) 2' MAX. (610mm)
2' MIN. (610mm) 4' MAX. (1.22m)
3' MIN. (914mm) 6' MAX. (1.86m)
4' MIN. (1.22m) 8' MAX. (2.48m)
5' MIN. (1.52m) 16' MAX. (4.8m)
16' MAX. (4.8m)
NOTE: V + V
1
+ H = MAX. 30' (9m)
VENTING WITH TWO (2) 90° ELBOWS
1' MIN. (305mm) 2' MAX. (610mm)
2' MIN. (610mm) 4' MAX. (1.22m)
3' MIN. (914mm) 6' MAX. (1.86m)
4' MIN. (1.22m) 8' MAX. (2.48m)
5' MIN. (1.52m) 16' MAX. (4.8m)
V+H+H
1
= 30 (9m) MAX. 16' MAX. (4.8m)
VENTING WITH TWO (2) 90° ELBOWS
V (FT.)
H + H
1
(FT.)
FOR MODEL SL-36 (CLEAN FACE VERSION):
V = 3-FEET (914mm) MINIMUM IN TABLES.
Figure 16. Venting with Two 90° Elbows
NOTE:MAXIMUM HORIZONTAL RUN
IS 11 (3.3M) ON UNITS EQUIPPED
WITH A VARIABLE VALVE.
Содержание SL-32
Страница 8: ...5 Figure 1 Diagram of the SL 36 Circulating Version ...
Страница 9: ...6 Figure 2 Diagram of the SL 36 Clean face Version ...
Страница 10: ...7 Figure 3 Diagram of the SL 36GDV ...
Страница 11: ...8 Figure 4 Diagram of the SL 32S and SL 32 ...
Страница 12: ...9 Figure 5 Diagram of the SL 32GDV ...
Страница 19: ...16 STRAIGHTOUTHORIZONTAL VENTING H Max Run 36 914 mm Figure 12 Straight Out Horizontal Venting ...