36
Figure 33. Standing Pilot Ignition Wiring Diagram
CAUTION
CAUTION
Step 8
Wiring the
Fireplace
NOTE: Electrical wiring must be installed by a
licensed electrician.
DISCONNECT REMOTE CONTROLS IF YOU
ARE ABSENT FOR EXTENDED TIME PERIODS.
THIS WILL PREVENT ACCIDENTAL FIREPLACE
OPERATION.
For Standing Pilot Ignition Wiring
Appliance Requirements
This appliance
DOES NOT
require 110-120 VAC to
operate.
WARNING
DO NOT CONNECT 110-120 VAC TO THE
GAS CONTROL VALVE OR REMOTE
WALL SWITCH OR THE APPLIANCE WILL
MALFUNCTION AND THE VALVE WILL
BE DESTROYED
.
Optional Accessories
Optional fan and remote control kits require that 110-
120 VAC be wired to the factory installed junction box
before the fireplace is permanently installed.
Remote Wall Switch
Position the remote wall switch in the desired position
on a wall. Run a maximum of 25 feet (7.8 m) or less
length of 18 A.W.G. minimum wire and connect it to
the fireplace ON/OFF switch pigtails.
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.