12
Vent system
termination kits
Vent system components
SL D-SERIES
D-SERIES
Figure 8. Vent Components and Terminations
Step 3
Installing the
Vent System
A. Vent System Approvals
Models SL-36, SL-32, and SL-32S are approved to
use SL D-series direct vent pipe components and
terminations. Models SL-32GDV and SL-36GDV are
approved to use D-series direct vent pipe. Approved
vent system components are labeled for identification.
NO OTHER VENTING SYSTEMS OR
COMPONENTS MAY BE USED
. Detailed
installation instructions are included with each vent
termination kit and should be used in conjunction with
this
Installers Guide
. The drawing below shows vent
system components and terminations.
Identifying Vent Components
The vent systems installed on this gas fireplace may
include one, two, or three 90°
elbow assemblies. The
relationships of vertical rise to horizontal run in vent
configurations using 90° elbows
MUST BE
strictly
adhered to. The rise to run relationships are shown in
the venting drawings and tables. Refer to the
diagrams on the next several pages.
NOTE:
Two 45° elbows may be used in place of one
90° elbow. You
MUST
always maintain the
MAXIMUM
and
MINIMUM
rise-to-run ratios in the
vent system.
Содержание SL-32
Страница 8: ...5 Figure 1 Diagram of the SL 36 Circulating Version ...
Страница 9: ...6 Figure 2 Diagram of the SL 36 Clean face Version ...
Страница 10: ...7 Figure 3 Diagram of the SL 36GDV ...
Страница 11: ...8 Figure 4 Diagram of the SL 32S and SL 32 ...
Страница 12: ...9 Figure 5 Diagram of the SL 32GDV ...
Страница 19: ...16 STRAIGHTOUTHORIZONTAL VENTING H Max Run 36 914 mm Figure 12 Straight Out Horizontal Venting ...