Heat & Glo • SL-550BE, SL-550BE-IPI • 2114-900 Rev. H • 2/08
28
Figure 7.6
Remove the insulation from the outer vent pipe.
Figure 7.7
To attach the fi rst section of vent pipe, make
sure to use the fi berglass gasket to seal between the fi rst
vent component and the outer fi replace wrap. Use 2 self
tapping screws to secure the gasket to the outer wrap.
Note:
Once the vent cap has been removed, it cannot be
reattached.
B. Rear Vent
Figure 7.8
Fold the tabs toward the center of the fi re plug
(90°) and remove the insulation gasket.
2 SCREWS
Figure 7.9
Cut the metal retaining band and fold the
sides out.
Figure 7.10
Fold the center parts of the retaining band
out and use to remove the vent cap.
Figure 7.11
Discard the vent cap, remove and discard
the insulation basket. Note: Once the vent cap has been
removed it CANNOT be reattached.
Figure 7.12
Attach the fi rst vent section (it will snap into
place). Slide the insulation gasket onto the vent section,
up against the appliance and over the tabs. Use two self-
tapping screws to secure gasket to outer wrap.