Heat & Glo • SL-550BE, SL-550BE-IPI • 2114-900 Rev. H • 2/08
22
INSTALLED
HORIZONTALLY
H
3
H
1
H
2
V
1
Rear Vent - Horizontal Termination
Venting with 2 elbows
H
1
MAX.
V
1
MIN.
H
2
MAX.
H
1
+ H
2
MAX.
1-1/2 ft.
457 mm
Back to back elbows
1 ft.
305 mm
2-1/2 ft.
762 mm
3 ft.
914 mm
1 ft.
305 mm
3 ft.
914 mm
6 ft.
1.8 m
5 ft.
1.5 m
3 ft.
914 mm
5 ft.
1.5 m
10 ft.
3.0 m
7 ft.
2.1 m
5 ft.
1.5 m
7 ft.
2.1 m
14 ft.
4.3 m
H
1
MAX. = 7 ft. (2.1 m)
H
1
+ H
2
MAX. = 14 ft. (4.3 m)
V
1
+ H
1
+ H
2
MAX. = 40 ft. (12.2 m)
Figure 5.14
Rear Vent - Horizontal Termination
Venting with 3 elbows
H
1
MAX.
V
1
MIN.
H
2
+ H
3
MAX.
H
1
+ H
2
+ H
3
MAX.
1-1/2 ft. 457 mm
Back to back elbows
1 ft.
305 mm
2-1/2 ft.
762 mm
3-1/2 ft.
1.1 m
1 ft.
305 mm
2 ft.
610 mm
5-1/2 ft.
1.7 m
5-1/2 ft.
1.7 m
2 ft.
610 mm
4 ft.
1.2 m
9-1/2 ft.
2.9 m
7-1/2 ft.
2.3 m
3 ft.
914 mm
6 ft.
1.8 m
13-1/2 ft.
4.1 m
H
1
MAX. = 7-1/2 ft. (2.3 m)
H
1
+ H
2
+ H
3
MAX. = 13-1/2 ft. (4.1 m)
V
1
+ H
1
+ H
2
+ H
3
MAX. = 40 ft. (12.2 m)
Figure 5.15
Note
: Use DVP Series
components only.
Note
: Use DVP Series
components only.
H
1
H
2
V
1