ECO CHOICE PELLET STOVE SERVICE MANUAL
FEED MOTOR TROUBLE-SHOOTING
1) TURN ON THERMOSTAT CIRCUIT AND MAKE SURE THAT THE CALL LIGHT IS ON
2) CHECK FOR POWER AT THE VACUUM SWITCH:
A. IF NO POWER FROM RED WIRE-----CHECK CONTROL BOX OR WIRE HARNESS
B. POWER ON RED FROM HARNESS BUT NO POWER ON RED GOING TO HOPPER SWITCH -----CHECK VACUUM SWITCH OR
VENT SYSTEM
3) CHECK FOR POWER AT THE ORANGE WIRE ON THE HOPPER SWITCH
A. IF NO POWER FROM ORANGE WIRE----CHECK WIRE HARNESS OR HOPPER SWITCH
B. IF POWER IS PRESENT-----CHECK #2 SNAP DISC
NOTE: REMEMBER THAT THE FEED CIRCUIT INITIAL FEED TIME IS 60 SECONDS. PUSH THE RESET
BUTTON BEFORE EACH TEST.
4) CHECK FOR POWER AT THE BLACK WIRE FROM #2 SNAP DISC:
A. IF NO POWER FROM BLACK WIRE----CHECK WIRE HARNESS OR SNAP DISC
B. IF POWER IS PRESENT-----CHECK FEED MOTOR
FEED MOTOR
VACUUM
SWITCH
JUNCTION BOX
FEED MOTOR CIRCUIT
WHITE
RED
WHITE
WHITE
BLACK
RED
RED
WHITE
ORANGE
RED
BLACK
#2 SNAP DISC
HOPPER SWITCH
CAPACITOR
CALL LIGHT
PAGE 10