ECO CHOICE PELLET STOVE SERVICE MANUAL
OPERATION FLOWCHART
FOLLOW THE PELLET STOVE OPERATION AND VERIFY THAT EACH COMPONENT IS COMING ON.
IF THAT COMPONENT IS NOT COMING ON, REFER TO THE TROUBLESHOOTING SECTION FOR THAT COMPONENT.
AFTER THAT PART HAS BEEN FIXED, PROCEED WITH THE OPERATION OF THE STOVE AND MAKE SURE THAT EACH OPERATION IS
TAKING PLACE.
THERMOSTAT
TURNS ON.
RED CALL LIGHT
ILLUMINATES
ON THE STOVE.
(START)
1
EXHAUST
BLOWER TURNS
ON.
2
IGNITER TURNS
ON.
3
VACUUM SWITCH
CLOSES.
4
ITEMS TO CHECK: POSSIBLE PROBLEMS OR FAILED COMPONENT
BOX 1: THERMOSTAT, THERMOSTAT WIRE, WIRE HARNESS, OR CONTROL BOX
BOX 2: EXHAUST BLOWER, CONTROL BOX, WIRE HARNESS
BOX 3: IGNITER, CONTROL BOX, WIRE HARNESS
BOX 4: VACUUM SWITCH, VACUUM HOSE, VENT OR HEAT EXCHANGER BLOCKAGE, DOOR SEAL
CALL LIGHT
PAGE 6