background image

A1710-3.3 en

High Pressure
Transducer

Mounting instructions

P3MBP

Содержание P3MBP

Страница 1: ...A1710 3 3 en High Pressure Transducer Mounting instructions P3MBP ...

Страница 2: ......

Страница 3: ...uctions 4 1 List of components supplied 7 2 Construction and operating mode 8 3 Mounting 9 4 Electrical connection 11 4 1 Cable extension 12 5 Measuring 13 5 1 Measuring dynamic pressures 13 6 Specifications in accordance with DIN 16 086 14 7 Dimensions in mm 16 ...

Страница 4: ... installation and assem bly coupled with careful operation Use as a component with a safety function does not come under appropriate use and the user must assess this himself in the sense of the Pressure Equipment Directive 97 23 EC General dangers in non observance of the safety instructions The pressure transducer corresponds to the state of the art and is safe to operate The pressure transducer...

Страница 5: ...there is a fire the device is rendered unusable The end of service life is reached if the zero signal has changed significantly Residual dangers are highlighted in this operating manual with the following symbols Symbol DANGER Meaning Maximum danger level Warns of an imminently dangerous situation in which failure to comply with safety requirements will result in death or serious physical injury S...

Страница 6: ...led and operated by qualified per sonnel strictly in accordance with the technical data relating to the safety requirements and safety rules and regulations listed It is also essential to comply with the statutory and safety regulations relevant to the particular application This also applies to the use of accessories Qualified personnel means persons familiar with the installation assembly commis...

Страница 7: ...ar 10000 bar 15000 bar Double cone seal with packing for nominal rated measuring range of 5 000 bar Order no 2 9289 5512 Double cone seal for nominal rated measuring range of 10 000 bar and 15 000 bar Order no 3 9219 0816 User manual Cable made of polyurethane with Lemosa connector male 2 9268 0835 ...

Страница 8: ... without too much extra work On the other hand the choice of output signal or the stresses and strains should be small enough for dynamic loading to be possible without the premature signs of material fatigue Any fluid or gas vapour that does not attack these steels is a suitable measurement medium The pressure transducer and its threaded connector are strengthened for the purpose of the pressure ...

Страница 9: ...the pressure connection by a tapered gasket of 58 in a beveled run in to the hole of 60 as is usual and successful in ultrahigh pressure technology The seal is made from corrosion resistant material the 5000 bar version from 1 4301 the 10 000 bar and 15 000 bar versions from 1 4542 To minimize the volume in the measurement hole dead volume packing is used for these measuring ranges This forms a un...

Страница 10: ...ting flange and not to the housing or cable entry The permitted tightening torque is 30Nm P3MBP 5000 M20 x 1 5 19 Relief aperture Double cone seal min 17 P3MBP 10 000 bar Seal with packing Ø3 5 Ø6 5 2 7 58o M20 x 1 5 19 min 17 2 3 Ø2 5 Ø6 5 58o Relief aperture Double cone seal Sealing cone Fig 3 1 Installing the pressure transducer ...

Страница 11: ...voltage Excitation voltage Measurement signal Sensor circuit available available available 2 7 9 8 10 5 white red blue green black gray orange yellow violet brown Transducer connection Available for future expansion 3 Inner shield insulated Outer shield to connector enclosure Solder side Lemosa connector FFA 2E 310 CLAC65 2 1 8 3 4 5 6 7 10 9 Abb 4 1 Electrical connection of the P3MBP pressure tra...

Страница 12: ...ed or at least made with safe stable terminals and installed so that they are watertight In the open air and or in a damp environment terminal boxes must be sealed When extending the six cores of the standard measuring cable and using a six wire circuit amplifier the cable length does not affect the measuring signal Measuring cables should not be laid parallel to high tension and control cir cuits...

Страница 13: ...aring The devices have reached the end of their service life if the zero signal has changed by more than 5 or if there is clearly visible and unscheduled defor mation and damage to the device 5 1 Measuring dynamic pressures When there is dynamic loading maximum pressure must not exceed the rated pressure The oscillation bandwidth peak to peak of the permitted pressure fluctuation must not exceed 7...

Страница 14: ...lerance t 0 2 t 0 4 t 0 5 Effect of temperature on the zero signal in the nominal rated range of the excitation voltage per 10K by reference to the nominal rated sensitivity in the nominal rated temperature range in the operating temperature range 0 1 0 15 0 2 0 25 0 2 0 25 Effect of temperature on sensitivity in the nominal rated range of the excitation voltage per 10K by reference to the actual ...

Страница 15: ...DIN 40 046 Impact acceleration m s2 1000 Impact duration ms 4 Impact form Half sine wave Mechanical specifications Pressure connection 1 P3MB M20 x 1 5 with sealing cone 58o in unit with packing for the measure ment hole Electrical connection Lemosa connector ERA 2E 310 SLL Bending radius static dynamic mm mm 35 75 Mounting position any Dimensions mm Ø25 x 123 Weight without cable approx g approx ...

Страница 16: ...20 x 1 5 25 Connecting cable 2 9268 0835 7 m long included in delivery Lemosa connector ERA 2E 310 SLL Abb 7 1 P3MBP 5000 bar 17 a f 27 M20 x 1 5 143 107 25 60o Lemosa connector ERA 2E 310 SLL Connecting cable 2 9268 0835 7 m long included in delivery Abb 7 2 P3MBP 10000 bar ...

Страница 17: ...17 P3MBP BlueLine A1710 3 3 en HBM ...

Страница 18: ...18 P3MBP BlueLine A1710 3 3 en HBM ...

Страница 19: ...19 P3MBP BlueLine A1710 3 3 en HBM ...

Страница 20: ... 45 D 64293 Darmstadt Tel 49 61 51 8 03 0 Fax 49 61 51 8039100 E mail support hbm com www hbm com Modifications reserved All details describe our products in general form only They are not to be understood as express warranty and do not constitute any liability whatsoever A1710 3 3 en ...

Отзывы: