15
P3MBP Blue
Line
A1710-3.3 en
HBM
Ambient conditions
Reference temperature
o
C
+23
Nominal (rated) temperature range
°
C
-10...+80
Operating temperature range
°
C
-40...+100
Storage temperature range
°
C
-50...+100
Impact resistance
(tested under DIN 40 046)
Impact acceleration
m/s
2
1000
Impact duration
ms
4
Impact form
Half sine wave
Mechanical specifications
Pressure connection
1-P3MB
M20 x 1.5 with sealing cone 58
o
in unit with packing for the measure-
ment hole
Electrical connection
Lemosa connector ERA.2E.310.SLL
Bending radius
static
dynamic
mm
mm
35
75
Mounting position
any
Dimensions
mm
Ø25 x 123
Weight without cable approx.
g
approx. 200
Protection system
IP67