Assembly Instructions M8146-EN
M8146-EN 2019-07
7/16
Piston with sleeve and seal
(O/ID T27099, T28434)
1.
Carry out preparation (
page 3).
For switching module (20)
2.
Proceed as follows to disassemble the multiphase
motor (M 5,6):
Fig. 9: Remove switching unit buffer (19)
CAUTION!
Risk of burns!
During operation, the multiphase motor (M 5,6)
becomes hot. Danger of burns, if touched.
Therefore:
– Wear thermal gloves when touching or let the
multiphase motor cool down.
In order to remove the switching buffer unit (19), disassemble
2x pipe couplings (label 1) and remove 2x screws (label 2).
Remove the switching buffer unit (19) on the side.
To disassemble the protection cover of the accumulator (16),
remove 2x screws (label 3).
Fig. 10: Remove the multiphase motor
M 5,6
NOTICE!
Observe following when disassembling the
multiphase motor:
- Positioning of the multiphase motors
Preparation page 3.
- Alignment of the groove of the coupling, to allow the
piston rod to extend
Fig. 15
Withdraw the cable connector of the multiphase motor (M 5.6).
Loosen the 4 fixing screws (label 4) (approx. 8
–10 mm).
Slightly pull out downwards the multiphase motor (M 5,6) and
move out of coupling.
Fig. 11: Remove the cover of the switching
module
3.
Proceed as follows to disassemble the cover:
Disassemble the flexible tube of the tool circuit exit (OUT M).
Disassemble the main line temperature sensor (BT 1).
Disassemble 8x screws (label 1) and remove cover.
4.
Carefully move out the piston rod upwards.
1
3
2
4
1
BT 1