Inspection 

1.

 

Proceed as follows for inspection: 

    

 

2.

 

Plug all main plugs and switch on the main switch. 

  

 

3.

 

Switch the system on with the 

 key and check tightness 

and functioning. 

 

4. 

Switch the system off with the 

 key.

 

 

5. 

Switch off all main switches.

 

 

6. 

Fit the covers correctly on the switching unit.

 

  

 

  

Parts list 

     

Pos 

Description 

O/ID 

O/ID 

T2

7

0

9

8

 

T2

7

0

9

9

 

T2

8

4

3

4

 

T2

7

1

0

1

 

T2

7

1

0

2

 

T2

7

5

9

5

 

T2

8

4

3

3

 

Pcs 

Pcs 

Pcs 

Pcs 

Pcs 

Pcs 

Pcs 

01 

Bush 18x4x33 (mounted) 

T25912 

02 

Ring 11x4x2,4 (mounted) 

T27139 

03 

Scraper ARLON (mounted) 

T27138 

04 

Circlip DIN 427 (mounted) 

N10411 

05 

Grease Barrierta L55/2 (mounted) 

H1056 

06 

Cylinder pin DIN 6325-4h6x30 (mounted) 

B1306553 

07 

O-Ring 10x2-FFKM75 (mounted) 

T25432 

08 

Seal 4x10x4-FFKM (mounted) 

T25590 

09 

Screw M4x6-TORX (mounted) 

B3061615 

10 

Piston complete 25 

T26658 

11 

Piston complete 22 

T28042 

12 

Seal Sigraflex 39x47x1 

T25808 

13 

Seal Sigraflex 29x37x1 

T26758 

14 

Seal Sigraflex 24x32x1 

T25838 

15 

Linear step motor type 57 with bracket 

T27430 

16 

Linear step motor with bracket 

T28036 

17 

Hexagon screw M4x8-A2 

B3061322 

18 

Hexagon screw M4x12-A2 

B1237837 

19 

Assembly instructions German 

M8146-DE 

20 

Assembly instructions English  

M8146-EN 

21 

Assembly instructions French 

M8146-FR 

  

 

Содержание M8146-EN

Страница 1: ...s M8146 EN Spare parts Vario 5 switching and buffer valve Contents Precondition 2 Procedure 2 Preparation 3 Sleeve and seal O ID T27098 4 Piston with sleeve and seal O ID T27099 T28434 7 Sealing set O...

Страница 2: ...y electric current Touching conductive parts causes a direct danger to life Therefore For all work on the electrical system for maintenance cleaning or repair work disconnect from the mains or disconn...

Страница 3: ...mbol 2 Proceed as follows to mount or disassemble the multiphase motors Display the menu page Service Support Profile support Set the parameter Positioning valve heating to 25 Set the parameter Positi...

Страница 4: ...2 Remove the multiphase motor M 5 6 NOTICE Observe following when disassembling the multiphase motor Positioning of the multiphase motors Preparation page 3 Alignment of the groove of the coupling to...

Страница 5: ...e 4 screws Fig 5 Visual control of the groove alignment WARNING Improper installation can cause material damage Wrongly mounted multiphase motors can lead to dysfunction and or material damage Therefo...

Страница 6: ...ceed as follows in order to replace the guide bush Remove the fixing screw label 5 holding the guide bush at the bottom of the switching 20 resp buffer module 21 Remove the guide bush label 6 NOTICE D...

Страница 7: ...mble the protection cover of the accumulator 16 remove 2x screws label 3 Fig 10 Remove the multiphase motor M 5 6 NOTICE Observe following when disassembling the multiphase motor Positioning of the mu...

Страница 8: ...leaking The re use of used seals can cause leaking Therefore seals are to be compulsory replaced after each disassembly of the cover WARNING Damages if leaking Leaking if torque is wrong Therefore Ti...

Страница 9: ...l damage Therefore Observe correct mounting visual control to check the engagement of the piston rod in the coupling Fig 15 Fig 16 Assemble the switching unit buffer 19 Connect the cable connector of...

Страница 10: ...y c Disassemble the temperature sensor of the buffer BT 3 Disassemble the 1 screw on the rear panel of the unit Disassemble 4x screws label 2 and remove cover 11 Carefully move out the piston rod upwa...

Страница 11: ...is wrong Therefore Tighten cover of the buffer module with 10 Nm Remove the old seal clean the sealing surface and place the new seal label 3 Fit the cover and tighten with the 4 screws Mount the 1 s...

Страница 12: ...refore seals are to be compulsory replaced after each disassembly of the cover WARNING Damages if leaking Leaking if torque is wrong Therefore Tighten cover of the switching module with 37 Nm Remove t...

Страница 13: ...screw on the rear panel of the unit Mount the return line temperature sensor BT 2 at the buffer module Connect flexible tube of the buffer entry b Fig 25 Mount the cover of the buffer module 6 Proceed...

Страница 14: ...ulator 16 remove 2x screws label 3 Fig 27 Remove the multiphase motor M 5 6 NOTICE Observe following when disassembling the multiphase motor Positioning of the multiphase motors Preparation page 3 Ali...

Страница 15: ...unit 19 with 2x pipe couplings label 8 as well as 2x screws label 9 on the base plate Mount the protection cover of the accumulator with two screws label 10 on the multiphase motor the buffer module M...

Страница 16: ...4 Circlip DIN 427 mounted N10411 1 1 1 05 Grease Barrierta L55 2 mounted H1056 1 1 1 06 Cylinder pin DIN 6325 4h6x30 mounted B1306553 1 1 1 07 O Ring 10x2 FFKM75 mounted T25432 1 1 1 08 Seal 4x10x4 FF...

Отзывы: