Assembly Instructions M8146-EN
M8146-EN 2019-07
14/16
Complete linear stepper motor
(O/ID T27595, T28433)
1.
Carry out preparation (
page 3).
on the multiphase motor, the switching module (M 5,6)
2.
Proceed as follows to disassemble the multiphase
motor (M 5,6):
Fig. 26: Remove switching unit buffer (19)
CAUTION!
Risk of burns!
During operation, the multiphase motor (M 5,6)
becomes hot. Danger of burns, if touched.
Therefore:
– Wear thermal gloves when touching or let the
multiphase motor cool down.
In order to remove the switching buffer unit (19), disassemble
2x pipe couplings (label 1) and remove 2x screws (label 2).
Remove the switching buffer unit (19) on the side.
To disassemble the protection cover of the accumulator (16),
remove 2x screws (label 3).
Fig. 27: Remove the multiphase motor
M 5,6
NOTICE!
Observe following when disassembling the
multiphase motor:
- Positioning of the multiphase motors
Preparation page 3.
- Alignment of the groove of the coupling, to allow the
piston rod to extend
Fig. 29.
Withdraw the cable connector of the multiphase motor (M 5.6).
Loosen the 4 fixing screws (label 4) (approx. 8-10 mm).
Slightly pull out downwards the multiphase motor (M 5,6) and
move out of coupling.
F
Fig. 28: Mount the multiphase motor M 5,6
3.
Proceed as follows to mount the multiphase motor (M 5,6):
NOTICE!
Observe following when mounting the multiphase
motor:
- Loosen the 4 fixing screws enough (approx.
8-10 mm) to enable an easier installation.
- Alignment of the groove of the coupling, to allow
the piston rod to retract (label 7
Engage the multiphase motor, turn into final position and fix
with the 4 screws.
1
3
2
4