Assembly Instructions M8146-EN
M8146-EN 2019-07
11/16
Fig. 20: Mount the cover of the buffer
module
14.
Proceed as follows to mount the cover of the buffer
module (21):
WARNING!
Damages if leaking!
The re-use of used seals can cause leaking.
Therefore:
– seals are to be compulsory replaced after each
disassembly of the cover.
WARNING!
Damages if leaking!
Leaking if torque is wrong.
Therefore:
– Tighten cover of the buffer module with 10 Nm.
Remove the old seal, clean the sealing surface and place the
new seal (label 3).
Fit the cover and tighten with the 4 screws.
Mount the 1 screw on the rear panel of the unit.
Mount the temperature sensor of the buffer (BT 3) at the cover.
Connect the flexible tube of the buffer exit (c).
15.
Proceed as follows to mount the multiphase motor (M 7):
Engage the multiphase motor, turn into final position and fix
with the two screws.
Connect cable plug of the multiphase motor.
16.
Carry out inspection (
page 16).
3
c