9.4.5 Software update
Proceed as follows in order to install a new user programme on an
individual unit:
NOTICE!
The "gba03Usr.upd", "SW51-1_xxxx.upd" or
"SW51-2_xxxx.upd" software must be in the root of
the data carrier. It may not be stored in a folder.
NOTICE!
During the software update, the Thermo-5 unit or
the Panel-5 control model and all products
connected to them may not be switched off.
Necessary tools:
USB data carrier with the current software
The latest software can be acquired from the HB-Therm
representative (
NOTICE!
Only USB data carriers in FAT32 format are
supported.
Run software update
Fig. 56: Connect USB data carrier
Fig. 57: Start USB software update
1.
Switch on main switch.
2.
Connect USB data carrier (Fig. 56).
3.
Display menu page
Profile
.
4.
Set parameter
User profile
to "Enhanced".
5.
Display menu page
Save/Load
.
6.
Select function
Start USB Software Update
and confirm with
the
key.
The data is loaded from the USB data carrier to the memory in
the USR-51. Do not disconnect the USB connection.
Conclusion of data transfer is indicated on the display. The
USB connection can now be disconnected.
The new software is written to the USR-51 flash. On
completion, an automatic restart is initiated.
7.
If required, the USB connection must be re-established to
install further data.
If necessary, the new software is written to the connected
GIF-51, DFM-51 or VFC-51 after the restart. This process can
take a few minutes. On completion, another restart takes
place.
The message
Ready to operate