HB-CL2
Cleaning Unit
Operation
52
O8305-EN 2022-01
8.1.2.2 Neutralization phase
In this phase, the cleaning agent is neutralized with the neutralizing
agent so that no aggressive medium is pumped into the outlet.
Neutralization occurs only in the interior tank.
Fig. 23: Set neutralization
NOTICE!
Local sewage regulations must be followed.
Information about neutralization can be taken from
the safety sheet or you can ask the manufacturer of
the cleaning agent about it.
The neutralization phase is automatically conducted or skipped or
a query is made, depending on how the
Neutralization
parameter is
set.
The
Neutralization
parameter is set as follows:
1.
Display the menu page
Settings \ Miscellaneous
.
2.
Set
Neutralization
to the desired value.
When set to "OFF", the neutralization phase is skipped.
When set to "ON", neutralization is started automatically.
When set to "enquiry", a query is made as to whether
neutralization should or should not be started.