Hayward Aqua Plus 16v Скачать руководство пользователя страница 12

9

Spa Heater2

Priority: 10 hours

Adjust the desired priority interval (Never, 1hr, 2hrs, 3hrs ...22hrs, 23hrs, Always)
Move to previous/next menu item

The spa heater priority setting will only appear if the system has been setup for “spa only” or “pool

and spa”and if priority has been enabled for Spa Heater2.  Choose “Never”, “Always” or a selectable

time interval. If an interval is selected, only Spa Heater2 will run when there is a call for heat.  After the

interval expires, both heaters will be allowed to operate until the desired temperature has been reached.

Pool

Priority: Never

 Heater2

Adjust the desired priority interval (Never, 1hr, 2hrs, 3hrs ...22hrs, 23hrs, Always)
Move to previous/next menu item

The pool heater priority setting will only appear if the system has been setup for “pool only” or “pool

and spa”and if priority has been enabled for Pool Heater2.  Choose “Never”, “Always” or a selectable

time interval. If an interval is selected, only Pool Heater2 will run when there is a call for heat.  After the

interval expires, both heaters will be allowed to operate until the desired temperature has been reached.

Spa Solar 

102°F

Adjust the desired spa temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off)
Move to previous/next menu item

The spa solar setting will only appear if the system has been setup for “spa only” or “pool and spa”

operation and the solar control is enabled.  The solar system will turn on whenever the pool/spa

valves are in the “spa only” position and the filter pump is running and the spa water temperature is

less than the desired temperature setting and solar heat is available.

Pool Solar

88°F

Adjust the desired pool temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off)
Move to previous/next menu item

The pool solar heater setting will only appear if the system has been setup for “pool only” or “pool

and spa” operation and the solar control is enabled.  The solar system will turn on whenever the pool/

spa valves are in the “pool only” or “spa spillover” position and the filter pump is running and the

pool water temperature is less than the desired temperature setting and solar heat is available.

VSP Speed Settings

+ to enter

Spa Filter Speed 1

95%

Filter Speed 1

95%

Push to access Variable Speed Pump Speed Settings
Move to previous/next configuration menu

Move to next menu item

Spa Speed

50%

Move to next menu item

only if Pool and Spa-Std and Filter is Variable Speed

only if an output is configured for a variable speed pump

only if Filter is Variable Speed

only if Pool and Spa-Dual and Spa Filter is Variable Speed

Set the desired Filter Speed 1 from the Filter Lowest to the Filter Highest 

Set the desired Spa Filter Speed 1 from the Spa Filter Lowest to Spa Filter Highest

Move to next menu item

Aux2 Speed

95%

Set the desired Aux2 Speed from 10% to 100%
Move to next menu item 

only if Aux2 is controlled by a variable speed pump

The Filter, Dual Equipment Spa Filter, and up to 6 Lights and Aux outputs can be configured to control

variable speed pumps. These settings allow you to select the desired speed of the variable speed

pump for each output used. The speed can be displayed in % or RPM, whichever is selected in the

Configuration Menu. For the Filter and Dual Equipment Spa Filter, when the output is on, the actual

speed of the pump(s) will be dependent on the minimum and maximum speeds set for that output in the

Configuration Menu.

Super Chlorinate

Off

Turn super chlorinate on or off
Move to previous/next menu item

This display only appears if the chlorinator function is enabled.  If an AQL-CHEM is being used, super

chlorinate will not be available if chemical sensing is enabled and ORP is in Auto Sensing (see AQL-

CHEM manual).

38

P

O

U

N

DS

 a

n

d

 (K

g

) O

F

 S

TAB

IL

IZ

E

R

 (

C

YA

NU

RI

AC

ID

) NE

E

D

ED

 F

O

R

 8

0 P

P

M

G

a

llo

n

s a

n

d

 (Lite

rs)

 o

f P

o

o

l/

S

p

w

at

er

Cu

rre

n

t

Sta

b

il

iz

er

Le

ve

l (

p

pm

)

 0 

ppm

20

 p

p

m

60

 p

p

m

30

 p

p

m

40

 p

p

m

50

 p

p

m

70

 p

p

m

80

 p

p

m

10

 p

p

m

12

,0

00

(4

50

00

)

8,0

00

(300

00

)

14

,0

00

(5

25

00

)

10

,0

00

(3

75

00

)

16

,0

00

(6

0

00

0)

18

,0

00

(6

75

00

)

20

,0

0

0

(7

50

00

)

22

,0

0

0

(8

25

00

)

32

,0

0

0

(1

20

00

0)

2

4,000

(9

00

00

)

3

4,000

(1

27

50

0)

26

,0

0

0

(9

75

00

)

36

,0

00

(1

35

00

0)

28

,0

00

(1

05

00

0)

38

,0

0

0

(1

42

50

0)

30

,0

0

0

(1

1

250

0)

40

,0

0

0

(1

50

00

0)

8.

0

(3.

6)

5.

3

(3

.6

)

8.

0

(3.

6)

8.

0

(3

.6

)

9.

4

(4

.3

)

6.

7

(4.

3)

9.

4

(4

.3

)

10.

7

(4

.9

)

12

.0

(5

.4

)

12

.0

(5

.4

)

13

.4

(6.

1)

14

.7

(6.

7)

21

.3

(9.

7)

16

.0

(7.

3)

22

.7

(10.

3)

18

.7

(8

.5

)

25

.3

(11.

5)

20

.0

(9.

1)

26

.7

(12.

0)

7.

0 )

(3.

2

4.

7

(3

.2

)

8.

2

(3.

7)

5.

8

(3

.7

)

10.

5

(4

.8

)

11

.7

(5

.3

)

12

.9

(5.

9)

18

.7

(8

.5

)

14

.0

(6.

4)

19

.8

(9.

0)

15

.2

(6

.9

)

21

.0

(9

.5

)

16

.4

(7

.4

)

22

.2

(10.

0)

17

.2

(8

.0

)

23

.3

(10.

5)

6.

0

(2.

7)

4.

0

(2.

7)

6.

0

(2

.7

)

6.

0

(2

.7

)

8.

5

(3

.9

)

7.

0

(3

.2

)

9.

0

(2.

2)

10

.0

(4

.5

)

10

.0

(4.

5)

14

.2

(6.

3)

11

.0

(5

.0

)

16

.0

(7

.2

)

13

.0

(5.

9)

18

.0

(8.

1)

14

.0

(6

.4

)

19

.0

(8

.6

)

15

.0

(6.

8)

20

.0

(9.

0)

5.

0

(2

.3

)

3.

3

(2

.3

)

5.

0

(2

.3

)

5.

9

(2

.7

)

4.

2

(2

.7

)

6.

7

(3.

0)

8.

4

(3

.8

)

6.

7

(3

.0

)

7.

5

(3.

4)

9.

2

(4

.2

)

13

.3

(6.

0)

10

.8

(4

.9

)

15

.0

(6

.7

)

11

.7

(5

.2

)

15

.8

(7

.1

)

12

.5

(5

.6

)

16

.7

(7

.5

)

4.

0

(1.

8)

2.

7

(1

.8

)

4.

0

(1

.8

)

4.

0

(1

.8

)

5.

7

(2

.6

)

4.

7

(2

.1

)

3.

3

(2.

1)

5.

4

(2

.4

)

7.

4

(3

.3

)

10

.7

(4

.8

)

8.

7

(3.

9)

12

.0

(5.

4)

9.

3

(4

.2

)

12

.7

(5

.7

)

10

.0

(4

.5

)

13

.3

(6.

0)

3.

0

(1.

4)

2.

0

(1.

4)

3.

0

(1

.4

)

3.

5

(1

.6

)

2.

5

(1.

6)

4.

5

(2.

0)

5.

5

(2

.5

)

8.

0

(3

.6

)

6.

5

(2.

9)

9.

0

(4.

1)

7.

0

(3

.2

)

9.

5

(4

.3

)

7.

5

(3

.4

)

10

.0

(4.

5)

2.

0

(.

91)

1.

3

(.

91)

2.

0

(.

91

)

2.

8

(1

.3

)

2.

3

(1

.1

)

1.

7

(1

.1

)

2.

7

(1

.2

)

3.

3

(1

.5

)

3.

7

(1.

7)

5.

3

(2

.4

)

4.

3

(2

.0

)

4.

7

(2

.1

)

6.

3

(2

.8

)

5.

0

(2

.3

)

6.

7

(3

.0

)

1.

0

(.

45)

0.

7

(.

45)

1.

2

(.

54)

0.

8

(.

54)

1.

4

(.

64)

1.

5

(.

68)

1.

7

(.

77)

1.

8

(.

82

)

2.

7

(1

.2

)

2.

2

(1.

0)

3.

0

(1.

3)

2.

3

(1

.1

)

3.

2

(1

.4

)

2.

5

(1

.2

)

3.

3

(1.

5)

0.

0

0.

0

0.

0

0.

0

0.

0

0.

0

0.

0

0.

0

0.

0

0.

0

0.

0

0.

0

0.

0

0.

0

0.

0

0.

0

0.

0

Содержание Aqua Plus 16v

Страница 1: ...required to increase Add baking soda to increase Stabilizer 60 80 ppm Add cyanuric acid to increase Calcium 200 400 ppm Add calcium to increase Electrolytic Cell inspect clean Refer to section in manu...

Страница 2: ...totheoriginalowner Proofofpurchaseisrequiredforwarrantyservice Ifwrittenproofofpurchaseisnotprovided themanufacturing date code will be the sole determinant of the date of installation of the product...

Страница 3: ...enu 32 Quick How To Operate the Spa Manually 33 Guide Operate the Spa Automatically 33 Set the Heater Temperature 33 Set the Chlorinator Output 33 Start Stop Superchlorination 34 Program a Timeclock 3...

Страница 4: ...solarheater Bothmanualandautomatic programmed operationare available All of the control functions can be programmed at a display keypad which is part of the main unit typically located near the pool e...

Страница 5: ...installing this product as part of a saline water purification system in a pool or spa using natural stone for coping or for immediately adjacent patios decking a qualified stone installation special...

Страница 6: ...Valve4 or Heater2 See Configuration Menu System Off remote displays or Service main unit display Air Sensor 94 F Cell Temp Sensor 77 F Solar Sensor Short circuit Water Sensor Open circuit Spa Sensor O...

Страница 7: ...tandard Relay Manual operation of all relays LIGHTS AUX1 AUX6 is identical Assuming that the relay iscurrentlyoff simplypresstheappropriatebuttontoturnontherelay Iftherelaydoesnotturnon itprobablyis d...

Страница 8: ...the time remaining will be displayed on the remote display keypad s Pressingthe SERVICE buttonagain willreturntheAquaPlus16vtonormal automatic operation SeeTrouble shooting DiagnosticInformationformor...

Страница 9: ...is invalid Cell Power Error If a chlorinator cell power error is detected on the printed circuit board No Flow Filter Pump If the filter pump is on and the flow switch indicates no flow for 15 minutes...

Страница 10: ...sary before adding salt High Salt Amps Minerals TheAqua Plus 16v will stop generating chlorine under certain high salt condi tionsinordertoprotecttheinternalelectronicsfromdamage Theonlywaytolowerthes...

Страница 11: ...er FILTER 39 System Maintenance Tomaintainmaximumperformance itisrecommendedthatyouopenandvisuallyinspectthecellevery3months oraftercleaningyourfilter TheAquaPlus16vwillremindyoutodothisbydisplayingth...

Страница 12: ...peed Set the desired Filter Speed 1 from the Filter Lowest to the Filter Highest Set the desired Spa Filter Speed 1 from the Spa Filter Lowest to Spa Filter Highest Move to next menu item Aux2 Speed 9...

Страница 13: ...s enabled This setting determines the speed of the pump during low speed pool or spillover operation This value can be set from Lowest Speed to 50 in 5 increments 50 is default For PS models using dua...

Страница 14: ...to the distance between the Base Receiver and the remote device being too great or may be due to interference caused by other RF equipment operating in the neighborhood Try using the Change Channel c...

Страница 15: ...and filter operation set to pool only the valves will switch to the pool only position Refer to page 12 for general notes regarding timeclock programming For two speed or variable speed pumps this set...

Страница 16: ...d stop times to previous next menu item or or Lights CountDn 0 20 Adjust time setting Manual On Off 0 05 0 10 0 015 Move to previous next menu item Note Separate chlorinator output levels for the pool...

Страница 17: ...the Lights relay it should be marked on the label inside the door Then press the appro priate button to turn on the jets blower Operate the Spa Automatically 1 Pressthe MENU buttonrepeatedlyuntil Time...

Страница 18: ...7P Adjust time setting Adjust time setting Manual On Off 0 05 0 10 0 15 Move between start and stop times to previous next menu item Move to previous next menu item Valve3 all 8 30A to 4 00P Valve3 0...

Страница 19: ...of the standardAqua Plus 16v functions The default selections are Button 1 Pool Spa Button 2 Filter Button 3 Lights Button 4 Heater1 Button 5 Valve3 Button 6 Valve4 Button 7 Aux1 and Button 8 Aux2 Di...

Страница 20: ...L 15 T CELL 15 GLX CELL 15 W 30 Group the valve operates when the Group function is initiated and shuts off when the Group function is terminated See valve3 Group section for operation information for...

Страница 21: ...ool Only and Spillover are available 29 NOTE The configuration for Valve3 and Valve4 are identical However if Heater2 was enabled then the Valve4 configuration will not appear a single relay is used t...

Страница 22: ...en they want to control the filter equipment Asheet of small name labels is included with theAqua Plus 16v main unit and each remote display keypad so that appropriate pushbuttons can be labeled the s...

Страница 23: ...name as a help to technicians who may service this system at a later date Aux1 Function Manual On Off default the aux relay will alternate between turning on and off when the aux button is pressed The...

Страница 24: ...d the lights output will be forced off when the external input is active This will have precedence over freeze protection Lights External Input Interlock is not available for solar low speed filter pu...

Страница 25: ...can be used to control other pool devices that may require these options The function of each option is shown below Manual On Off the lights relay will alternate between turning on and off when the LI...

Страница 26: ...lter is configured for 2 speed operation During default operation high speed mode is used whenever the solar heater is on If Allow Low Speed is enabled low speed pump operation will be allowed during...

Отзывы: