Hayward Aqua Plus 16v Скачать руководство пользователя страница 10

7

40

Troubleshooting and Diagnostic Information

The Aqua Plus 16v provides 2 different tools to aid in troubleshooting any problems that may occur in your pool

and/or spa system.  The Service mode will allow you to disable automatic operation and manually control most of

the equipment (the heater and general purpose Valve3 output are the exceptions).  The Diagnostic Menu will

provide some detailed information regarding system operation.

While both of the features are primarily intended for the use of the professional service technician, their function is

fully explained below.  If you believe your system is not operating properly or have questions regarding the opera-

tion, call the Hayward Technical Service Dept. from Monday through Friday, 8AM to 8PM EST at 908-355-

7995.

Service Mode

The main unit keypad has a SERVICE button that is used primarily during servicing of the pool equipment.

If you want to completely disable the automatic operation and operate the system manually, you can put the system

into Service or Service-Timed mode by pressing the “Service” button.  Pressing the “SERVICE” button once will

switch the system into service mode which means that all automatic functions are disabled, the optional remote

display/keypads are disabled (except for manual turn off for emergencies).  The outputs can be manually controlled

by pressing the buttons on the local display/keypad.  The red “SERVICE” LED will be illuminated and the Aqua

Plus 16v will remain in this mode of operation until manually taken out of service mode.

Pressing the “SERVICE” button again will cause the Aqua Plus 16v to switch to service-timed mode which is very

similar to service mode, except that the Aqua Plus 16v will automatically return to normal operation after 3 hours.

During service timed operation, the “SERVICE” LED will flash and the time remaining will be displayed on the

remote display(s).

Pressing the “SERVICE” button again, will return the Aqua Plus 16v to normal (automatic) operation.

Check System Indicator

The “CHECK SYSTEM” LED will alert you when the Aqua Plus 16v detects any of the following conditions that

are abnormal and require attention for optimal operation of your pool. Press “<“ or “>” to view all of the existing

“Check System” conditions.

Inspect Cell 

-- For optimum operation, you will need to inspect the Aqua Plus 16v chlorinator cell approxi-

mately every 3 months and clean the cell if necessary. The Aqua Plus 16v will automatically remind you when it

is time and display “Inspect Cell, + to reset” as part of the rotating Default Menu. Clean the cell and then press

the “+” button during the “Inspect Cell” display to reset the timer.

Low Salt/Minerals or Very Low Salt/Minerals 

-- When the salt is too low the Aqua Plus 16v will generate

less chlorine and the life of the cell is degraded. Check the cell and clean if necessary before adding salt.

High Salt/Amps/Minerals 

-- The Aqua Plus 16v will stop generating chlorine under certain high salt condi-

tions in order to protect the internal electronics from damage. The only way to lower the salt level is to partially

drain the pool and add fresh water.

Water/Pool Sensor 

-- If the water or pool (if Dual Equipment) sensor is either an open or short circuit.

Air sensor -

- If the freeze protection feature is enabled (Configuration Menu/ Filter Config.) and the air sensor

is either an open or short circuit.

Solar sensor -

- If Solar is enabled and the solar sensor is either an open or short circuit.

Spa sensor for Dual Equipment-

- If  dual equipment spa sensor is either an open or short circuit.

Chlorinator Cell sensor -

- If the chlorinator function enabled (Configuration Menu/Chlorinator) and the cell

sensor is either an open or short circuit.

Programming Menu
Flowchart

denotes conditional items

PS-4 only

PS-4 only

default menu

day and time

water temperature

air temperature

chlorinator setting

salt level

reason pump is running (not scheduled)

inspect cell

reason hi-speed is running (not scheduled)

countdown time remaining

heater control status

system manual off

check system error

group active

filter vsp speed/reason

spa filter vsp speed/reason

lights/aux speed/reason

pH/ORP levels

settings menu

spa heater1 temperature

pool heater1 temperature

spa heater2 temperature

pool heater2 temperature

spa heater2 priority

pool heater2 priority

spa solar temperature

pool solar temperature

vsp speed settings

superchlorinate

spa chlorinator setting

pool chlorinator setting

aux colorlogic settings

day and time

backlit display light

beeper

teach wireless remote

wireless channel

maintenance menu

pH calibration wizard

clean probe wizard

timers menu

pool filter 1 or hi-speed 1

pool filter 2 or lo-speed 1

pool filter 3 or hi-speed 2
pool filter 4 or lo-speed 2

spa filter 1 or hi-speed

spa filter 2 or lo-speed

spa

lights
aux1
aux2

valve3

valve4

superchlorinate

diagnostic menu

chlorinator diagnostics

instant salt

pH/orp levels

flow switch

cell temperature sensor

water/pool sensor

spa sensor

air sensor

solar sensor

vsp speed/power

main software revision

display software revision

expansion unit software revision

chemistry sense module software

vsp software revision

RF base software revision

6 button spa side software revision

digital spa side software revision

colorlogic module software revision

colorlogic light software revision

configuration menu

chlorinator

chemistry config. Wizard

pool/spa

filter

spa filter

heater1

heater2

solar

colorlogic

external input active state

lights
aux1
aux2

valve3
valve4

6 button spa side remote

digital spa side remote

remote menus

7-day or weekend/weekday timeclock

12 hour or 24 hour time format

ºF or ºC

vsp speed (% or rpm)

reset colorlogic to default

reset to default

Содержание Aqua Plus 16v

Страница 1: ...required to increase Add baking soda to increase Stabilizer 60 80 ppm Add cyanuric acid to increase Calcium 200 400 ppm Add calcium to increase Electrolytic Cell inspect clean Refer to section in manu...

Страница 2: ...totheoriginalowner Proofofpurchaseisrequiredforwarrantyservice Ifwrittenproofofpurchaseisnotprovided themanufacturing date code will be the sole determinant of the date of installation of the product...

Страница 3: ...enu 32 Quick How To Operate the Spa Manually 33 Guide Operate the Spa Automatically 33 Set the Heater Temperature 33 Set the Chlorinator Output 33 Start Stop Superchlorination 34 Program a Timeclock 3...

Страница 4: ...solarheater Bothmanualandautomatic programmed operationare available All of the control functions can be programmed at a display keypad which is part of the main unit typically located near the pool e...

Страница 5: ...installing this product as part of a saline water purification system in a pool or spa using natural stone for coping or for immediately adjacent patios decking a qualified stone installation special...

Страница 6: ...Valve4 or Heater2 See Configuration Menu System Off remote displays or Service main unit display Air Sensor 94 F Cell Temp Sensor 77 F Solar Sensor Short circuit Water Sensor Open circuit Spa Sensor O...

Страница 7: ...tandard Relay Manual operation of all relays LIGHTS AUX1 AUX6 is identical Assuming that the relay iscurrentlyoff simplypresstheappropriatebuttontoturnontherelay Iftherelaydoesnotturnon itprobablyis d...

Страница 8: ...the time remaining will be displayed on the remote display keypad s Pressingthe SERVICE buttonagain willreturntheAquaPlus16vtonormal automatic operation SeeTrouble shooting DiagnosticInformationformor...

Страница 9: ...is invalid Cell Power Error If a chlorinator cell power error is detected on the printed circuit board No Flow Filter Pump If the filter pump is on and the flow switch indicates no flow for 15 minutes...

Страница 10: ...sary before adding salt High Salt Amps Minerals TheAqua Plus 16v will stop generating chlorine under certain high salt condi tionsinordertoprotecttheinternalelectronicsfromdamage Theonlywaytolowerthes...

Страница 11: ...er FILTER 39 System Maintenance Tomaintainmaximumperformance itisrecommendedthatyouopenandvisuallyinspectthecellevery3months oraftercleaningyourfilter TheAquaPlus16vwillremindyoutodothisbydisplayingth...

Страница 12: ...peed Set the desired Filter Speed 1 from the Filter Lowest to the Filter Highest Set the desired Spa Filter Speed 1 from the Spa Filter Lowest to Spa Filter Highest Move to next menu item Aux2 Speed 9...

Страница 13: ...s enabled This setting determines the speed of the pump during low speed pool or spillover operation This value can be set from Lowest Speed to 50 in 5 increments 50 is default For PS models using dua...

Страница 14: ...to the distance between the Base Receiver and the remote device being too great or may be due to interference caused by other RF equipment operating in the neighborhood Try using the Change Channel c...

Страница 15: ...and filter operation set to pool only the valves will switch to the pool only position Refer to page 12 for general notes regarding timeclock programming For two speed or variable speed pumps this set...

Страница 16: ...d stop times to previous next menu item or or Lights CountDn 0 20 Adjust time setting Manual On Off 0 05 0 10 0 015 Move to previous next menu item Note Separate chlorinator output levels for the pool...

Страница 17: ...the Lights relay it should be marked on the label inside the door Then press the appro priate button to turn on the jets blower Operate the Spa Automatically 1 Pressthe MENU buttonrepeatedlyuntil Time...

Страница 18: ...7P Adjust time setting Adjust time setting Manual On Off 0 05 0 10 0 15 Move between start and stop times to previous next menu item Move to previous next menu item Valve3 all 8 30A to 4 00P Valve3 0...

Страница 19: ...of the standardAqua Plus 16v functions The default selections are Button 1 Pool Spa Button 2 Filter Button 3 Lights Button 4 Heater1 Button 5 Valve3 Button 6 Valve4 Button 7 Aux1 and Button 8 Aux2 Di...

Страница 20: ...L 15 T CELL 15 GLX CELL 15 W 30 Group the valve operates when the Group function is initiated and shuts off when the Group function is terminated See valve3 Group section for operation information for...

Страница 21: ...ool Only and Spillover are available 29 NOTE The configuration for Valve3 and Valve4 are identical However if Heater2 was enabled then the Valve4 configuration will not appear a single relay is used t...

Страница 22: ...en they want to control the filter equipment Asheet of small name labels is included with theAqua Plus 16v main unit and each remote display keypad so that appropriate pushbuttons can be labeled the s...

Страница 23: ...name as a help to technicians who may service this system at a later date Aux1 Function Manual On Off default the aux relay will alternate between turning on and off when the aux button is pressed The...

Страница 24: ...d the lights output will be forced off when the external input is active This will have precedence over freeze protection Lights External Input Interlock is not available for solar low speed filter pu...

Страница 25: ...can be used to control other pool devices that may require these options The function of each option is shown below Manual On Off the lights relay will alternate between turning on and off when the LI...

Страница 26: ...lter is configured for 2 speed operation During default operation high speed mode is used whenever the solar heater is on If Allow Low Speed is enabled low speed pump operation will be allowed during...

Отзывы: