7
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Operation
Operation of both remotes is straightforward. Pushbuttons are used to access the options for
each function and LED lights indicate the status of that function. The AQL-SS-D has a digital
display which is used to set and view temperatures.
Use the label sheets supplied with your remote control to properly label each function. Both re-
motes contain backlit “windows” which allow the labels to be seen clearly, day or night. Remove
the desired label and adhere it to proper window. Refer below for specific operation information.
AQL-SS-6B
When connected to units running software version 2.40 or greater, the AQL-SS-6B’s six pushbut-
tons can be assigned to operate various functions. With older version software, the AQL-SS-6B
will control fixed functions (see page 1).
Backlights behind the function labels allow the user to clearly see which output is being controlled
during the day or night. LED lights next to the labels will indicate the status of the function.
The operation of functions that are controlled by the AQL-SS-6B will vary. On/Off functions like
“Lights” and “Aux’s” operate in the same manner. Other functions like “Heater” and “Pool/Spa”
operate differently. Operation information for each function is shown below.
If “Pool and Spa - Std” (shared equipment for pool & spa)
Pool/Spa:
Pressing the “Pool/Spa” button will alternate between Pool Only and Spa Only. If Spill-
over is enabled, the button will alternate operation between Pool Only, Spa Only and Spillover. The
LED will only light when in the Spa Only mode.
Filter:
When the “Filter” button is pressed, the pool filter pump will turn on or off, depending on
its previous condition. The LED will turn on when the pump is on. If a 2-speed pump is used, the
button will cycle the pump from Hi-speed to Lo-speed to Off. In this case, the LED will blink when
in Lo-speed and be on steady when in Hi-speed. The LED will also blink while in “Cooldown”
mode.
Lights & all Aux’s:
When the “Lights” or “Aux” buttons are pressed, the feature that is connected
to the corresponding Pro Logic/Aqua Logic relay will turn on or off, depending on its previous
condition. The LED will light when the function is on.
Heater:
When the “Heater” button is pressed, the Pro Logic/Aqua Logic will turn the heater on for
5 minutes, regardless of the heater temperature setting. After 5 minutes, the heater will continue
to run if the water temperature is less than the heater temperature setting. When the heater
turns off, the Pro Logic/Aqua Logic’s heater control will be in an automatic state. Pushing the
heater button anytime while the heater is on, will shut the heater off and put the Pro Logic/Aqua
Logic’s heater control in a manual off state.
NOTE: The LED indicator will illuminate whenever the heater is running. Also, the Pro Logic/Aqua
Logic will never allow the water temperature to exceed 104°F (40ºC).