USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
8
If “Pool and Spa - Dual” (separate equipment for pool & spa)
Pool Only/Spillover:
Pressing the “Pool/Spa” button will alternate between Pool Only and Spillover
mode (if enabled). Spillover only works when the Spa filter pump is off. The LED will not be lit.
Filter:
When the “Filter” button is pressed, the pool filter pump will turn on or off, depending on
its previous condition. The LED will turn on when the pump is on. If a 2-speed pump is used, the
button will cycle the pump from Hi-speed to Lo-speed to Off. In this case, the LED will blink when
in Lo-speed and be on steady when in Hi-speed. The LED will also blink while in “Cooldown”
mode.
Lights & all Aux’s except Aux 1:
When the “Lights” or “Aux” buttons are pressed, the feature that
is connected to the corresponding Pro Logic/Aqua Logic relay will turn on or off, depending on
its previous condition. See information below for Aux 1 operation. The LED will light when the
function is on.
Spa Heater:
When the “Heater” button is pressed, the Pro Logic/Aqua Logic will turn the heater
on for 5 minutes, regardless of the heater temperature setting. After 5 minutes, the heater will
continue to run if the pool water temperature is less than the heater temperature setting. When
the heater turns off, the Pro Logic/Aqua Logic’s heater control will be in an automatic state.
Pushing the heater button anytime while the heater is on, will shut the heater off and put the Pro
Logic/Aqua Logic’s heater control in a manual off state.
NOTE: The LED indicator will illuminate whenever the heater is running. Also, the Pro Logic/Aqua
Logic will never allow the water temperature to exceed 104°F (40ºC).
Aux1 (Spa Filter):
When Pool and Spa - Dual is selected, the “Aux1” button controls the Spa Filter
and operates similar to the “Filter” function.
AQL-SS-D
The AQL-SS-D can only be used with Pro Logic PS models and Aqua Logic PS models running
software version 2.40 or greater. It is similar to the AQL-SS-6B except that it has 2 more function
buttons as well as 3 buttons underneath the LED display. The 8 functions operate in the same
manner as the AQL-SS-6B. Refer to page 7 for this information.
The 3 buttons under the LED display are used to set temperatures, view temperatures and turn
the display off. Pushing the center button will cycle the display to view “Spa” temperature, view
“Air” temperature, view “Set” spa heater temperature and the last push will turn off the display.
While the display is off, 3 dots will appear. This mode is convenient at night when the lit display
is not desired. The up and down buttons are used to set the temperature of the heater when in
“Set” mode. The displayed option (“Spa”, “Air” and “Set”) will initially be displayed for 3 seconds,
then the actual temperature will be shown and remain on until the center button is pushed. To
quickly determine which temperature is being displayed, air temperature will always be displayed
with a decimal point, water temperature will have no decimal point and the set temperature will
always blink. When the display is off, three dots will appear.