![Hawk XLT HT IEX Series Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/hawk/xlt-ht-iex-series/xlt-ht-iex-series_instruction-manual_2109383027.webp)
Instructions Manual
High-pressure piston pumps - XLT/XLTI ATEX series
Cod. doc.
M.I.01
Rev.
0
Page 27 of 32
This Manual is the property of the Manufacturer; any reproduction in any form, even partial, is prohibited.
Controlling pipes and couplings (not supplied by LEUCO)::
Check for any leaks from the couplings.
Leaks can normally be eliminated by tightening the couplings correctly.
Restore the seal in case of leakage from the couplings on the suction line.
Check the state of any hoses.
Pipes or hoses must be replaced if you note any sign of wear, damage, or look scraped or blown.
Controlling the filter (not supplied by LEUCO):
Check the state of the filter cartridge.
If the filter cartridge is blocked or damaged, refer to the instructions provided by the filter manufacturer and restore the
filter to its optimum filtering capacity.
Controlling the level of the oil:
Check when the pump is level and cold.
Check the amount of oil using the level indicator (located at the back of the pump body, see subsection 2.1, letter G).
Top up with oil, if necessary, as instructed in subsection 3.7, through the oil plug (located on the top of the pump body,
see subsection 2.1, letter C).
Replacing the oil:
Place the machine where the pump is fitted into a perfectly level position with the pump warm. Do not spill any oil.
Dispose of oil correctly according to current legislation.
Use a suitably large recipient to collect the spent oil.
Unscrew the drainage cap (1) and wait for all the oil to drain out.
Screw the drainage cap back down.
Unscrew the oil cap (letter C, subsection 2.1 or n.2 in the illustration below).
Fill with the new oil using the filling hole up to the correct level (as described in the subsection on “Controlling the oil
level”).
Screw the filling cap back down.
Refer to any additional specifications and/or company procedures and the operating manual for the final
machine for information on any other maintenance work.
If you note any anomaly, you must identify the cause and solve the problem before operating the machine
again.
Contact the Manufacturer for information on any maintenance work not included in this manual or its
attached documents.