4.10. EMERGENCY PLATFORM LOWERING AND TROUBLESHOOTING.
Emergency lowering
In case of a malfunction, use the emergency control on the ground control panel.
Emergency manual lowering.
If the emergency control does not work, the platform can be lowered manually.
On H12 SD and H15 SD (See photo 10).
•
Pull the handle, and the platform will come down by
gravity.
•
To stop lowering, release the handle.
On H18SDX (See photo 11).
•
Pull the handle, and the platform will come down by
gravity.
•
To stop lowering, release the handle.
Photo 10 : Emergency lowering.
Photo 11 : Emergency lowering.
WARNING.
Lowering an overloaded platform,
using the emergency manual lower function, is prohibited.
WARNING.
When performing emergency manoeuvres from the ground with the extension out, it is essential to
ensure there are no obstructions under the platform (wall, cross bar, power line, etc…)