125
4000429690
E 11.15
US / GB
OPTIMUM 8 - OPTIMUM 1931 E
E
- Trouble shooting and diagram
Failure
Code
C
Description
F12 : Internal faults
CAN Fault
Check
wiring
F12.01 (A)
1
No data is received from upper control box card
Key OFF / ON
Check wiring
2
No data is received from lower control box screen
Key OFF / ON
Check wiring
4
COMBIACX : Module doesn't receive any CAN messages from ACEX module
Check wiring
Check the Can Bus connections
Disconnect (master controller) and measure resistance between CR34 (5)and CR34
(10). If it is not 60 Ohm +/- 5%, check continuity of the bus wires
• CR34 (10) to CR38 (10) to CR45 (4)
Ensure that all the connectors pins are properly in place and the connectors are free of
moisture or oxidation
8
ACEX : Module doesn't receive any CAN messages from COMBIACX module
Check wiring
Check the Can Bus connections
Disconnect (master controller) and measure resistance between CR34 (5)and CR34
(10). If it is not 60 Ohm +/- 5%, check continuity of the bus wires
• CR34 (10) to CR38 (10) to CR45 (4)
Ensure that all the connectors pins are properly in place and the connectors are free of
moisture or oxidation
16
No time (date/hour) update (problem with screen communication)
E2P Read
/ Write
Error
Change
calc.
F12.02 (D)
1
EEPROM failure status error
2
EEPROM failure stack full
4
COMBIACX : Wrong slip profile parameters or EEPROM damage
Perform a CLEAR EEPROM. If problem persists, replace the controller
8
COMBIACX : Software or hardware error has been detected, default parameters are
applied
Execute a CLEAR EEPROM operation
Cycle power to clear the fault :
• If the alarm disappears, the previously stored parameters will have been replaced by
the default parameters
• If the fault is not cleared, replace the controller
16
ACEXWrong slip profile parameters or EEPROM damage
Perform a CLEAR EEPROM. If problem persists, replace the controller
32
ACEXSoftware or hardware error has been detected, default parameters are applied
Execute a CLEAR EEPROM operation
Cycle power to clear the fault :
• If the alarm disappears, the previously stored parameters will have been replaced by
the default parameters
• If the fault is not cleared, replace the controller
64
Problem reading EEPROM at start-up
Restart machine
E2P
Param
Reset
Check
SETTING
S
F12.04 (D)
ID of software loaded into machine is different from the ID stored into EEPROM : All
machine parameters have been reset and must then be set again (speeds, ramps,
options, configs, access code level 2, failure counters and calibration data)
Содержание OPTIMUM 1931 E
Страница 2: ...2 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E...
Страница 10: ...10 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E A Preface Foreword Notes...
Страница 19: ...19 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E C Familiarization Familiarization Notes...
Страница 50: ...50 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E D Inspection and maintenance schedule Notes...
Страница 54: ...54 4000429690 E 11 15 US GB General data Structural part inspection MS0001 Notes...
Страница 64: ...64 4000429690 E 11 15 US GB General data Breaking test procedure MS0004 Notes...
Страница 72: ...72 4000429690 E 11 15 US GB Electric Electrical wiring MS0025 Notes...
Страница 76: ...76 4000429690 E 11 15 US GB Scissor arm Scissor arms screw Periodical checks MS0073 Notes...
Страница 88: ...88 4000429690 E 11 15 US GB Platform Removal replacement of platform assembly MS0095 Notes...
Страница 98: ...98 4000429690 E 11 15 US GB Scissors Removal replacement of Scissor pack MS0096 Notes...
Страница 102: ...102 4000429690 E 11 15 US GB Chassis Calibration steering MS0097 Notes...
Страница 116: ...116 4000429690 E 11 15 US GB Ground control box HAULOTTE Activ Screen MS0106 Notes...
Страница 134: ...134 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E E Trouble shooting and diagram 3 Electric diagram...
Страница 135: ...135 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E E Trouble shooting and diagram...
Страница 136: ...136 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E E Trouble shooting and diagram...
Страница 137: ...137 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E E Trouble shooting and diagram 4 Hydraulic diagram...
Страница 138: ...138 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E E Trouble shooting and diagram Notes...
Страница 148: ...148 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E F Records...