- Trouble shooting and diagram
Failure
Code
C
Description
F08 : Electric circuit
Supply
F08.04
(D)
1
COMBIACX : Power capacitors voltage does not increase at start-up
Ensure that no external device is connected to the batteries.
Check battery, power cables and connections.
2
COMBIACX : The controller detects an overvoltage or under voltage condition
Overvoltage threshold is 35V, under voltage threshold is 9.5V.
If the fault appears at start-up or during standby : Check that no external device (relays switching, solenoids
energizing/de-energizing... ) is connected to the batteries, creating down-going pulses.
If no voltage transient is detected on the supply line and the alarm appears every time the key is switched
ON : Replace the controller
Check if the fault appears during driving acceleration (under voltage condition detected) : Check battery
charge ; check for damaged batteries, battery cables and connections
Check if the fault appears during release braking (overvoltage condition detected) : Check line contactor
contact, battery power cable connection
4
COMBIACX : At start-up, the battery voltage is too low or too high ( < 0.8 Vbatt or > 1.2 Vbatt)
Check that the controller SET BATTERY parameter value matches the battery nominal voltage ( 24VDC ).
Check that the TESTER MENU / BATTERY VOLTAGE parameter shows same value as the battery voltage
measured with a voltmeter. If it does not match, then do a ADJUST BATTERY function
If the default still appears, replace the battery
8
COMBIACX : A low logic level of Key-Off has been detected during start-up diagnosis
Check that no external device (relays switching, solenoids energizing/de-energizing... ) is connected to the
batteries, creating down-going pulses
Check the connection of power cabled to the battery terminal, positive and negative, to MC DRIVE and to
+Batt and -Batt, which must be screwed with a torque comprised in the range 5,6Nm-8,4Nm
If no voltage transient is detected on the supply line and the alarm appears every time the key is switched
ON : If no voltage transient is detected on the supply line and the alarm appears every time the key is
switched ON
16
ACEXPower capacitors voltage does not increase at start-up
Ensure that no external device is connected to the batteries.
Check battery, power cables and connections.
32
ACEX : The controller detects an overvoltage or under voltage condition
Overvoltage threshold is 35V, under voltage threshold is 9.5V.
If the fault appears at start-up or during standby : Check that no external device (relays switching, solenoids
energizing/de-energizing... ) is connected to the batteries, creating down-going pulses.
If no voltage transient is detected on the supply line and the alarm appears every time the key is switched
ON : Replace the controller
Check if the fault appears during driving acceleration (under voltage condition detected) : Check battery
charge ; check for damaged batteries, battery cables and connections
Check if the fault appears during release braking (overvoltage condition detected) : Check line contactor
contact, battery power cable connection
64
ACEX : At start-up, the battery voltage is too low or too high ( < 0.8 Vbatt or > 1.2 Vbatt)
Check that the controller SET BATTERY parameter value matches the battery nominal voltage ( 24VDC ).
Check that the TESTER MENU / BATTERY VOLTAGE parameter shows same value as the battery voltage
measured with a voltmeter. If it does not match, then do a ADJUST BATTERY function
If the default still appears, replace the battery
12
8
ACEX : A low logic level of Key-Off has been detected during start-up diagnosis
Check that no external device (relays switching, solenoids energizing/de-energizing... ) is connected to the
batteries, creating down-going pulses
Check the connection of power cabled to the battery terminal, positive and negative, to MC DRIVE and to
+Batt and -Batt, which must be screwed with a torque comprised in the range 5,6Nm-8,4Nm
If no voltage transient is detected on the supply line and the alarm appears every time the key is switched
ON : If no voltage transient is detected on the supply line and the alarm appears every time the key is
switched ON
Содержание OPTIMUM 1931 E
Страница 2: ...2 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E...
Страница 10: ...10 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E A Preface Foreword Notes...
Страница 19: ...19 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E C Familiarization Familiarization Notes...
Страница 50: ...50 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E D Inspection and maintenance schedule Notes...
Страница 54: ...54 4000429690 E 11 15 US GB General data Structural part inspection MS0001 Notes...
Страница 64: ...64 4000429690 E 11 15 US GB General data Breaking test procedure MS0004 Notes...
Страница 72: ...72 4000429690 E 11 15 US GB Electric Electrical wiring MS0025 Notes...
Страница 76: ...76 4000429690 E 11 15 US GB Scissor arm Scissor arms screw Periodical checks MS0073 Notes...
Страница 88: ...88 4000429690 E 11 15 US GB Platform Removal replacement of platform assembly MS0095 Notes...
Страница 98: ...98 4000429690 E 11 15 US GB Scissors Removal replacement of Scissor pack MS0096 Notes...
Страница 102: ...102 4000429690 E 11 15 US GB Chassis Calibration steering MS0097 Notes...
Страница 116: ...116 4000429690 E 11 15 US GB Ground control box HAULOTTE Activ Screen MS0106 Notes...
Страница 134: ...134 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E E Trouble shooting and diagram 3 Electric diagram...
Страница 135: ...135 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E E Trouble shooting and diagram...
Страница 136: ...136 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E E Trouble shooting and diagram...
Страница 137: ...137 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E E Trouble shooting and diagram 4 Hydraulic diagram...
Страница 138: ...138 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E E Trouble shooting and diagram Notes...
Страница 148: ...148 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E F Records...