4 Install
13
8. If required, the signalling
line K1 UL can be
connected to the K1
signalling socket (E).
• The signalling socket
allows the discharging
power pack to be reset
externally.
• The signalling socket
allows to be pulse
externally the discharging power pack.
• The discharging power pack can be monitored by means of
the output monitoring voltage of the signalling socket.
NOTE:
Leave the unused signal socket closed or secure it with the sealing
cap to prevent the ingress of environmental influences. The sealing
cap must be clean, dry and free of grease.
Configuration of K1
signalling socket:
A External pulse
B External reset
NOTE:
The discharging power pack can also be reset by pressing the reset
pushbutton or switching off/on (mains switch or mains voltage).
More information in chapter "Operate over the signalling socket K1"
on page 15.
9. The discharging power pack is ready for operation.