6 Troubleshooting
20
6.2
Flow chart
The reset pushbutton flashes.
Discharging power
pack is faulty
Switch off discharging power pack and
unplug ionizing units.
Disconnect signalling line K1 UL from
the discharging power pack. Switch on
the discharging power pack.
yes
Switch off discharging power pack and
connecting a ionizing unit.
Switch on the discharging power pack.
This ionizing unit
has a fault.
(Short circuit)
Ionizing system is ok
no
no
no
yes
yes
This ionizing unit
has a fault.
(Short circuit)
Switch off discharging power pack and
connecting another ionizing unit.
Switch on the discharging power pack
etc.
Reset pushbutton
flashing?
Reset pushbutton
flashing?
Reset pushbutton
flashing?