4.4.
Capacitor connection.
Connect a capacitor to connector numbers 9 and 10, polarity does not matter.
4.5.
Connecting the motor..
The motor connection should be made in accordance with the description:
7 COM
– common engine wire
11 OPEN
– motor cable to activate it in the opening direction
8 CLOSE
– motor cable to actuate it in the closing direction
1 PE
– PE protective conductor
4.6.
Connection of signal lighting.
Connecting the bulb with a power not exceeding 15W / 230V should be made to connectors
5 and 6:
5
– the neutral wire of the lamp
6
– lamp phase wire
When using the flashing light function, do not connect the signaling
device with the built-in internal circuit breaker. This can damage the driver.
When using a signaling device with a built-in circuit breaker, make sure that
the light function is set to continuous mode before connecting it.
Fluorescent lamps must not be used as traffic lights.
4.7.
Power connection.
The last stage of connection is to connect the controller power supply, connect in turn the
wires:
2 PE
– protective conductor
3 L
– the phase conductor
4 N
– the neutral conductor
Protect the controller power supply by using a residual current circuit
breaker.
5. Put the quick connectors back into the controller.
Before starting the device, check the power supply, grounding and
wiring. The cables should not be too long, it is not allowed to wind the
remaining cable in the so-called "loops", simultaneous routing of the
controller power cables, motor and control cables.
6.
Place the barrier in the middle by hand.
7.
Turn on the power.
8.
Check the opening direction.
Pressing the manual control button or the transmitter that has been programmed activates
the door in the opening direction, if otherwise, swap the wires connected to the OPEN (11) and
CLOSE (8) connectors, after disconnecting the power supply first.
9.
Program the remote control trasmitter.
Содержание 535Y
Страница 1: ...HATO 535Y AUTOMATIC BARRIER OPERATING MANUAL...
Страница 6: ......
Страница 23: ...NOTES...
Страница 26: ......
Страница 27: ...HATO TRADE SP ZOO ul eromskiego 1 41 205 Sosnowiec POLAND tel 032 785 25 42 www hato com pl DISTRIBUTOR SELLER...