7
Form No. GM5AHM_CN-0520
Installation Site Requirements
The installation site must meet specific requirements for safe
and proper installation of the unit.
• Make sure the countertop material is designed to withstand
long periods of hot food holding temperatures. Contact the
manufacturer of the countertop material for application
information.
• Make sure the installation site provides the proper minimum
clearances for adjacent surfaces.
WARNING
FIRE HAZARD: Do not install units above or around
combustible surfaces. Discoloration or combustion
could occur. Units must be installed in non-combustible
surroundings only.
Minimum Clearance Requirements—
Non-Combustible Surroundings
Model
A
B
C
GM5AH and
GM5AHL
254 mm
(10″)
0 mm
(0″)
25 mm
(1″)
C
B
Shelf
Back or Side W
all
Countertop
A
Minimum Clearances
NOTE: Strip heaters can be installed over a steam table. Follow
the minimum clearance requirements.
Heat Pattern Dimension
(approximately 305 mm [12″]—
determined by mounting height)
Recommended
Height
330–406 mm
(13″–16″)
Recommended Element Height for the GM5AH Series in all widths
NOTE: The size of heat pattern will vary depending on the
height of the unit.
Installing the Unit
Use the following procedure to install the unit using the supplied
angle brackets.
NOTE: Units come with a 1.5 m (5
′
) power cord and plug.
NOTICE
Damage to any countertop material caused by heat
generated from Hatco equipment is not covered under
the Hatco warranty. Contact manufacturer of countertop
material for application information.
1. Determine the exact mounting location on the underside of
the shelf.
NOTE: The attached angle brackets provide 25 mm (1
″
)
clearance between the unit and an overshelf.
NOTE: Units can be mounted to a flat shelf or a shelf with
rolled/flanged edges. The unit must be installed with
the minimum 25 mm (1
″
) clearance measured from the
lowest part of the overshelf. For example, a shelf with
a 25 mm (1
″
) flanged edge would require the unit to be
installed 51 mm (2
″
) below the underside of the shelf. If
minimum distances are not maintained, damage to the
surroundings and/or failure to the unit could occur.
2. Fasten the angle brackets to the underside of the shelf
using appropriate fasteners (not supplied by Hatco). Make
sure the unit is facing the desired direction with the wire
leads on the proper side before fastening the unit to the
shelf.
Shelf
Angle bracket
fastened to
underside of shelf.
25 mm (1")
Minimum
Gap
25 mm (1")
Minimum
Gap
Flat Shelf Installation
3. Route the element wire leads and LED wire leads toward
the installation location for the control box.
INSTALLATION