8
Form No. GM5AHM_CN-0520
INSTALLATION
Installing a Vertical Surface Mounted
Control Box
Use the following procedure to install the vertical surface
mounted control box.
WARNING
The Vertical Surface Mounted Control box must be
mounted in a vertical surface. Mounting this control box in
a horizontal surface may result in the collection of liquids
and lead to electric shock.
NOTICE
Install remote-mounted control box outside of areas subject
to temperatures above 104°F (40°C). Excessive temperatures
will cause controls to overheat, malfunction, and fail.
IMPORTANT NOTE:
Remote-mounted control boxes and control switches must
be installed in a cool, dry location as far away from any
heat zone as possible. Do not mount control boxes directly
on, under, or above unit. Do not mount control boxes in
direct contact with any heated surface or near any steam
generating equipment.
1. Cut and drill the appropriate holes in the vertical surface
where the control box will be installed. Refer to the "Control
Box Cutout and Screw Hole Dimensions" illustration for
cutout and screw hole dimensions.
NOTE: Make sure the control box installation location provides
enough space behind the vertical surface for the depth
of the control box and electrical connections.
2. Route the element wire leads and the LED wire leads from
the unit to the control box through the cutout and make
electrical connections.
3. Plug the power cord into a properly grounded electrical
receptacle of the correct voltage, size, and plug
configuration. See the SPECIFICATIONS section for
details.
Power Cord
Power
to Unit
Access
Cover
Vertical Surface Mounted Control Box Electrical Connections
4. Position the control box into the cutout opening through the
front side. Make sure that none of the electrical wires are
pinched or stressed.
5. Apply a 6 mm (1/4″) bead of NSF-approved silicone sealant
where the control box flange will contact the cabinet surface.
6. Fasten the control box to the vertical surface using four
screws (not supplied).
DO NOT INSTALL BOX
IN THIS AREA
DO NOT INSTALL
BOX IN THIS AREA
Screw
Control Box
Control
Box
Cutout
Heat
Installing the Vertical Surface Mounted Control Box
217 mm (8-1/2")
211 mm
(8-5/16")
55 mm
(2-3/16")
68 mm
(2-11/16")
6.5 mm
(1/4")
Control Box Cutout and Screw Hole Dimensions