8 HASCO hot runner
6.1 Alarm displays
Thermocouple error
Lights continuously when a thermocouple is broken or reversed.
The actual value display shows "- - -".
If automatic actuator operation is activated, the current heating power of the controller
appears in the set point display after a short time.
Temperature deviation
Lights during the heating phase until the setpoint temperature is reached,
and if the temperature falls below the set limit temperatures.
Excess current
Lights up if the set maximum current is exceeded.
Heating circuit interrupted
Lights up in the event of a defective FF16A fuse on the module, or with a heating failure or
cable fracture.