Hasco H1250 Series Скачать руководство пользователя страница 11

Instruction manual H1250

 

   HASCO hot runner   11 

The "Temperature deviation" alarm display will light up. 

Once the set point temperature on the unit has been reached, production can be run with the calculated parameters. 
The "Temperature deviation" alarm display will go out. 

If malfunctions occur during start-up, the reason for the error will be shown by the appropriate displays on the control unit 
(see Page 5). 

The soft start can be bypassed by pressing the automatic control / PRG button combination.  

The automatic mode button must be pressed first in this case.

 

After switching the unit off and on with the mains power switch, the soft start will be active again. 

The soft start can be permanently deactivated via parameter 17 (page 8). 

Note! The soft start provides protection for the electric components. 

It is recommended to run a soft start! 

 

8.2 Manual mode 

Manual mode is called up by pressing the "Manual mode" button. 

The desired heating output (%) is set with the aid of the arrow buttons. 

 

9. Programming 

 

 

The programming function is activated by pressing the PRG button (for about 3 sec.). 
The first menu item "P00" appears in the actual value display.  

The setpoint value display shows the value of the parameter. 

This can be changed with the arrow buttons. 

Pressing the PRG button twice again will call up the next parameter. 

To exit program mode, the PRG button must be pressed for approx. 3 sec. 

The control unit confirms that the changed parameters have been permanently saved by the decimal point in the top right-
hand display blinking for a short time. 

The temperature control will continue to operate normally in parameter mode.

 

 

9.1. Reset all parameters / factory settings 

To return all the parameters to the factory setting, the "PRG" button must be briefly pressed at the same time as the 
operating voltage is switched on with the mains power switch. "RES" appears in the display. 

 

 

Содержание H1250 Series

Страница 1: ...H1250 Basezone Control unit Operating instructions...

Страница 2: ......

Страница 3: ...m the basis for the safe handling of HASCO hot runner technology The instructions and information given here and particularly the safety rules must be followed under all circumstances The general safe...

Страница 4: ...connection 6 4 1 Pin diagram 6 5 Button and display functions 7 6 Displays 7 6 1 Alarm displays 8 6 2 Function displays 9 7 Function buttons 10 8 Controller start up 10 8 1 Switching on Soft Start 10...

Страница 5: ...ements as per the EU Directives 3 Technical Data H1250 1x16 H1250 2x16 H1250 4x16 Dimensions B x H x T 210 x 160 x 100 210 x 160 x 100 210 x 175 x 160 Mains voltage standard 230VAC 10 50 60 Hz 400V 3N...

Страница 6: ...from the mains power Before the H 1250 is opened it must be disconnected from the mains power 4 Electrical connection The H 1225 power signal cable is to be used for the power and thermocouple connect...

Страница 7: ...alue Parameter Setting 6 Displays Actual value display Actual temperature in C Parameter menu items Set point display Set point temperature in C Power output in amps and heating output in see switch o...

Страница 8: ...the controller appears in the set point display after a short time Temperature deviation Lights during the heating phase until the setpoint temperature is reached and if the temperature falls below th...

Страница 9: ...he control unit is switched off and on again with the main power switch Previous set point is reactivated Third set point value temperature increase Display for raising set point temperature factory s...

Страница 10: ...k of the cables connect the tool to the control unit Switch on the control unit at the main switch Use the arrow buttons to activate the set point display and enter the desired set point value The con...

Страница 11: ...rt 8 2 Manual mode Manual mode is called up by pressing the Manual mode button The desired heating output is set with the aid of the arrow buttons 9 Programming The programming function is activated b...

Страница 12: ...eactivated P08 Lower temperature limit 10 0 500 0 deactivated P09 Temperature alarm mode 1 0 Off 1 ON P10 Min load current 0 2 A 0 16 A 0 deactivated P11 Max heating output for soft start 35 0 100 P12...

Страница 13: ...rts must be disconnected from the mains power The system must also be safeguarded against being unintentionally turned on again The H 1225 power signal cables must be regularly inspected for mechanica...

Страница 14: ...www hasco com Built to Run...

Отзывы: