Hasco H1250 Series Скачать руководство пользователя страница 12

12   HASCO hot runner    

10. Menu items 

 

 

 

Menu items  

Ex works 

Value range 

Comment 

P00  Offset cold junction temperature  

0  

-9.9 – 9.9 

°C 

P02  Re-determine control parameters 

0 – 1 

1= activated 

P03  Edit established dead time 

 X 

0 – 100 

 

P04  Manual entry of dead time 

 

0 – 100 

 

P05  Display residual time soft start 

 

sec. 

P06  Soft start duration 

300 

120 – 999 

sec. 

P07  Upper temperature alarm limit 

10 

0 – 500 

0 = deactivated 

P08  Lower temperature limit 

10 

0 – 500 

0 = deactivated 

P09  Temperature alarm mode 

0 = Off / 1 = ON 

  

P10  Min. load current   

0.2 A 

0 – 16 A 

0 = deactivated 

P11  Max. heating output for soft start 

35% 

0 – 100% 

 

P12  Max. heating output after soft start 

100% 

0 – 100% 

 

P13  Max. heating output in manual mode 

100% 

0 – 100% 

 

P14  Conversion 50 / 60Hz 

50Hz 

50 – 60Hz 

 

P15  Language 

0 – 1 

0 = German 

1 = English 

P16  Display brightness 

0 – 1 

 

P17  Soft start  ON = 1 / OFF = 0 

0 -1 

 

P18  No soft start as of actual temperature   

100°C 

50 – 100°C 

  

P19  Max. setpoint value 

500°C 

30 – 500°C 

 

P20  Automatic switch to manual mode 

0 -1 

0 = deactivated 

 

 

 

 

 

 

 

 

 

 

Содержание H1250 Series

Страница 1: ...H1250 Basezone Control unit Operating instructions...

Страница 2: ......

Страница 3: ...m the basis for the safe handling of HASCO hot runner technology The instructions and information given here and particularly the safety rules must be followed under all circumstances The general safe...

Страница 4: ...connection 6 4 1 Pin diagram 6 5 Button and display functions 7 6 Displays 7 6 1 Alarm displays 8 6 2 Function displays 9 7 Function buttons 10 8 Controller start up 10 8 1 Switching on Soft Start 10...

Страница 5: ...ements as per the EU Directives 3 Technical Data H1250 1x16 H1250 2x16 H1250 4x16 Dimensions B x H x T 210 x 160 x 100 210 x 160 x 100 210 x 175 x 160 Mains voltage standard 230VAC 10 50 60 Hz 400V 3N...

Страница 6: ...from the mains power Before the H 1250 is opened it must be disconnected from the mains power 4 Electrical connection The H 1225 power signal cable is to be used for the power and thermocouple connect...

Страница 7: ...alue Parameter Setting 6 Displays Actual value display Actual temperature in C Parameter menu items Set point display Set point temperature in C Power output in amps and heating output in see switch o...

Страница 8: ...the controller appears in the set point display after a short time Temperature deviation Lights during the heating phase until the setpoint temperature is reached and if the temperature falls below th...

Страница 9: ...he control unit is switched off and on again with the main power switch Previous set point is reactivated Third set point value temperature increase Display for raising set point temperature factory s...

Страница 10: ...k of the cables connect the tool to the control unit Switch on the control unit at the main switch Use the arrow buttons to activate the set point display and enter the desired set point value The con...

Страница 11: ...rt 8 2 Manual mode Manual mode is called up by pressing the Manual mode button The desired heating output is set with the aid of the arrow buttons 9 Programming The programming function is activated b...

Страница 12: ...eactivated P08 Lower temperature limit 10 0 500 0 deactivated P09 Temperature alarm mode 1 0 Off 1 ON P10 Min load current 0 2 A 0 16 A 0 deactivated P11 Max heating output for soft start 35 0 100 P12...

Страница 13: ...rts must be disconnected from the mains power The system must also be safeguarded against being unintentionally turned on again The H 1225 power signal cables must be regularly inspected for mechanica...

Страница 14: ...www hasco com Built to Run...

Отзывы: