Instruction manual H1250
HASCO hot runner 5
1. Introduction
The HASCO H 1250 control unit offers precision control and practically orientated operation.
2. Special Features
- 1 to 2 control zones
- Optimum control performance
- Programmable soft start
- Power display in amps and % output
- Clear alarm diagnosis
- Manual or automatic switch to manual mode
- Boost function
- Temperature reduction
- Thermocouple monitoring
- Heating circuit monitoring
The H 1250… control unit satisfies the key protection requirements
as per the EU Directives.
3. Technical Data
H1250/1x16
H1250/2x16
H1250/4x16
Dimensions (B x H x T)
210 x 160 x 100
210 x 160 x 100
210 x 175 x 160
Mains voltage standard
230VAC
±10%
/ 50 – 60 Hz
400V 3N ~ ±10% / 50–60 Hz
400V 3N ~±10% / 50–60 Hz
Unit protection external
16A
16A / Phase
32A / Phase
Power output
Max. 3600W
Max 3600W / zone
Max 3600W / zone
Thermocouple
Fe-CuNi Typ J
Fe-CuNi Typ J
Fe-CuNi Typ J
Control range
30 – 500°C
30 – 500°C
30 – 500°C
Control accurancy
>1°C under optimum conditions
>1°C under optimum conditions
>1°C under optimum conditions
Ambient temperature
10 – 40°C
10 – 40°C
10 – 40°C
Power fuse
FF 16A / 500V
FF 16A / 500V
FF 16A / 500V
Protection type
IP 21 / EN 60529
IP 21 / EN 60529
IP 21 / EN 60529