Microwave Sensor Installation
Locate the mounting holes on the back of both the left and right side of the
bale chute (figure 1).
Mount the rear microwave moisture mounting brackets 001-2601 (figure 2) on
the holes using two 3/8” x 3 1/2" hex bolts, nuts and lock washers located in
parts bag D.
Attach the microwave moisture sensors to each mounting bracket. Sensor 006-4641MTX will be mounted or
the left side of the bale chute (figure 3). Sensor 006-4641MRX will be mounted on the right side (figure 4).
Mount the sensors with the wire connection port toward the baler.
Locate the MWM wiring harness (006-6650MWL) in the kit. Start by locating the connector with the white heat
shrink label marked RX. Connect this connector to the sensor mounted on the right side chute (006-
4641MRX).
If connecting to a
moisture only system
route the MWM harness (006-6650MWL) to the DCP on the baler and
remove the green capped terminating resistor (006-5650Z) on the pump modular port, connecting the MWM
sensors. Secure the harness.
If connecting to a
complete applicator system
route the MWM harness (006-6650MWL) to the Pump Controller
(006-5672) on the pump plate next to the tank and remove the green capped terminating resistor (006-5650Z)
on the pump modular port. Connect the MWM harness to the pump controller in the modular port. Secure the
harness. The green resistor is no longer needed.
Figure 1
Figure 3
Figure 4
Figure 2