background image

 

Installation of End of Bale Sensor 

 

The end of bale sensor determines the position of the needles on the baler.  When the needles cycle the 
sensor communicates this information to the Dual Channel Processor. This information is used for job records 
and will be used by the optional Bale Identification systems. Follow the steps below to mount the sensor. 
 

 

End of bale sensor bracket (001-4648) will be used. Cutoff excess metal not used during installation.  

 

 

 

 

 

4-

7/8” 

(13cm) 

3-

1/8” 

(8cm) 

15” 

(37cm) 

 

Mount the end of bale sensor bracket (001-

4648) as shown. Mark and drill two 5/16” (8mm) holes and attach 

the bracket using two 1/4” x 1” bolts, locks, flats, and nuts. Mount the sensor in the 8” (20cm) hole location, 
keep the sensor 1/4" (7mm) from the needle and tighten both nuts. Cut off excess metal past the sensor.  Run 
the sensor cable up to the Dual Channel Processor and secure to the baler. 
 

 

 
 
 
 
 

 

Sensor hole location 

8 (20cm)” 

 

001-

4648 with 6” (15cm) 

hole used for sensor 

001-

4648 with 12” (30cm) 

hole used for sensor 

Содержание 602A

Страница 1: ...1 602A 17 INST Imp Metric 6 22 Installation Manual Model 602A Microwave Moisture Bale Chute System AGCO 2100 2200 Series Balers Forage Harvester...

Страница 2: ...ication preservatives for hay Harvest Tec system meets the Directive 2006 42 EC of the European Parliment and the Council of 17 May 2006 and other applicable European Directives including Directive 20...

Страница 3: ...d Bale Rate Harness 8 Installation of the Main Harness the Power Communication Harness 8 Installation of Bluetooth Receiver 8 Microwave Sensor Installation 9 10 Wiring Diagram 11 Pin Outs 12 14 Common...

Страница 4: ...back of the manual Right and Left sides are determined by facing in the direction of forward travel System Requirements The Baler Processor must have Version 3 3 or higher C1000 monitor must have Vers...

Страница 5: ...wn are on the right twine box looking at the back of the baler Mark and drill the four 3 8 10mm holes and install DCP with four 5 16 x 1 bolts locks flats and nuts If your baler is not listed below mo...

Страница 6: ...otch must be moved out an additional 1 2 13mm Use the template in the back of the manual for hole spacing Place the spacer plate 001 6707E over the precut holes Attach with 5 16 x 1 2 Allen head bolts...

Страница 7: ...ill be used Cutoff excess metal not used during installation A B C 4 7 8 13cm 3 1 8 8cm 15 37cm Mount the end of bale sensor bracket 001 4648 as shown Mark and drill two 5 16 8mm holes and attach the...

Страница 8: ...e the Bluetooth Receiver 030 6672B Recommended location is as close to the iPad being used as possible Connect the Power Communication harness 006 6650TM E to the bottom of the receiver right New for...

Страница 9: ...650MWL in the kit Start by locating the connector with the white heat shrink label marked RX Connect this connector to the sensor mounted on the right side chute 006 4641MRX If connecting to a moistur...

Страница 10: ...er Connect an extension harness and route to rear of baler Secure with cable ties Route the rest of the harness along the existing wiring toward the top of the chamber The wire from the stuffer sensor...

Страница 11: ...ce on the tractor 9 Connect the Chute Wire Harness 006 6650MWL into the Pump Controller port on the DCP 10 Connect Microwave Sensors 006 4641MTX 006 4641MRX to the Chute Wire Harness 11 Connect the St...

Страница 12: ...wer Pin 4 Gray Shield Pin 5 Green HT Can Low Pin 6 Yellow HT Can Hi Pin 7 Orange Can1 Hi Pin 8 Black Ground from TSD Pin 9 Black Ground from DCP Pin 10 Blue Can1 Low Bluetooth Receiver on Harness 006...

Страница 13: ...wer Connector on Dual Channel Processor DCP Pin 1 Red 12V Power from tractor Pin 2 Black Ground from tractor Pin 3 Orange Keyed power Star Wheel and Bale Rate Sensor Connector on DCP Pin 1 Blue 12V Po...

Страница 14: ...mpression Chamber Harness 006 6650MWL Pin 1 Red Power Pin 2 Black Ground Pin 3 N A Not Used Pin 4 Brown Signal Microwave Pre Compression Chamber Harness 006 6650MWL RX Pin 1 Black Ground Pin 2 Red Pow...

Страница 15: ...erformed A zero adjust should be performed on initial installation It is also recommended during a zero adjust calibration at the beginning of each season 10 When reading moisture with microwave senso...

Страница 16: ...ltage should be constant between 12 and 14 volts 3 Install voltage surge protection on tractors alternator Display reads under or over power 1 Verify with multi meter actual voltage Voltage range shou...

Страница 17: ...l insert w Ref 10 2 11 Twine guard left for AGCO 001 4645H 1 4 Snap ring per side 006 4641K 2 Twine guard right for AGCO 001 4644H 1 5 Washer per side w 006 4641K 2 w bale rate sensor holes 6 Dust sea...

Страница 18: ...r 001 5650X 1 5 DCP Main Control LS 600 AUTO 006 6671LS 1 6 DCP Baler Harness 30 FT 006 6650LS2 E 1 7 DCP Tractor Harness 006 6650TM E 1 8 Dust Plugs 006 5651PLUGS 1 9 DCP Baler Interface Harness 006...

Страница 19: ...MTX 1 3 End of Bale Extension Harness 20 006 7400MXT 1 4 MWM Pre Compression Harness 006 6650MWL 1 5 Microwave RX Sensor 006 4641MRX 1 6 End of Bale Bracket Stuffer Bracket 001 4648SS 1 7 End of Bale...

Страница 20: ...g plastic nut from USB plug before connecting the wires Black White 5 The wires will then be hooked to the designated terminals on the bottom of the USB plug 6 Drill a 1 1 8 hole in the preferred moun...

Страница 21: ...ove the round locking plastic nut from USB plug before connecting the wires Black White 5 The wires will then be hooked to the designated terminals on the bottom of the USB plug 6 Drill a 1 1 8 hole i...

Страница 22: ...22 Notes...

Страница 23: ...to deny the warranty request at their discretion Parts must be returned through the selling dealer and distributor transportation charges prepaid This warranty shall not be interpreted to render Harve...

Страница 24: ...24 HARVEST TEC LLC P O BOX 63 2821 HARVEY STREET HUDSON WI 54016 PHONE 715 386 9100 1 800 635 7468 FAX 715 381 1792 Email info harvesttec com...

Отзывы: