5 – Remote Control
ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
Version 2.11, August 2011
Harris Corporation
5-11
Intraplex Products
Figure 5-9. DS0 Management Communication in Multiple CrossConnect Configurations
5.1.2.3 CrossConnect Mapping for DS0 Management Communications
When using DS0 management communication in a ring, star, or other complex network configuration,
you must give special attention to programming the CrossConnect systems. The DS0 time slot
designated to transport the network management communications must pass through each common
module in the control group. The designated time slot for network communications is programmed in a
pass-through configuration on a CrossConnect system. Figure 5-10 demonstrates an example of the
pass-through configuration for CrossConnect systems A and B.