5 – Remote Control
ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
Version 2.11, August 2011
Harris Corporation
5-5
Intraplex Products
BAUD and PAR are both underscored, indicating that there is an additional menu layer beneath them
that contains more functions. BAUD and PAR may be thought of as subgroups within the SIO function
group. The Lock function is not underscored, indicating that it is a standard function and therefore
does not have an additional menu layer beneath it.
Table 5-2. SIO Group
Function
Setting
Description
(baud
rate)
BAUD
110
110 bps
300
300 bps
1200
1200 bps
2400
2400 bps
4800
4800 bps
9600
9600 bps
19,2
19,2 kbps
57,6
57,6 kbps
exit
When exit is displayed, press up on the SET/NEXT switch to exit the BAUD subgroup and
display the PAR function.
(parity)
PAR
Spac
Space. No parity: all parity bits set to zero.
Mark
Mark. No parity: all parity bits set to one.
Even
Even parity. Each parity bit is set so that the total number of ones in each data byte,
including the parity bit, is even.
Odd
Odd parity. Each parity bit is set so that the total number of ones in each data byte,
including the parity bit, is odd.
exit
When exit is displayed, press up on the SET/NEXT switch to exit the PAR subgroup and
display the Lock function.
Lock
When the Lock function is displayed, press up twice on the SET/NEXT switch to toggle the state of
the remote port between locked and unlocked. The green (top) light turns on when the port is
locked; the red (bottom) light turns on when the port is unlocked.
To exit the Lock function and display the BAUD subgroup, press down on the SET/NEXT switch. To
exit the SIO group, press up and down on the GROUP switch.
5.1.1.4 Baud Rate Setting
To display and change the current remote port baud rate:
1.
Press down repeatedly on the GROUP switch until SIO appears.
2.
Press down repeatedly on the SET/NEXT switch until the display reads BAUD.
3.
Press up once on the SET/NEXT switch. The display now reads 110 which is the first available baud
rate, 110 bits per second (bps).
4.
Press down on the SET/NEXT switch additional times to see the other available baud rates: 300,
1200, 2400, and so on. Note that the green (top) light turns on when the display shows the
currently set baud rate, and the red (bottom) light turns on when the display shows any other
baud rate.
5.
To change the current baud rate, press down on the SET/NEXT switch until the display shows the
desired baud rate, and then press up twice on the SET/NEXT switch. After the first press the green
(top) light blinks, indicating that a change is about to be made. After the second press, the light
turns on continuously, indicating that the current baud rate now equals the displayed baud rate.
Содержание ACS-163
Страница 4: ...This page is left blank intentionally...
Страница 12: ...No header here viii Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 52: ...No header 2 30 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 98: ...No header here 4 24 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 144: ...No header 5 46 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 166: ...No header 6 22 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 172: ...No header 7 6 Harris Corporation Intraplex Products This page is left blank intentionally...