ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
4 – Setup & Configuration
Version 2.11, August 2011
4-20
Harris Corporation
Intraplex Products
4.7.1
CM-5RTD Setup
If your ACS-160 Series multiplexer has the optional delay capability, it has a CM-5RTD common
module. The CM-5RTD module allows you to program a time delay in the receive T1 path.
4.7.1.1 Delay Feature Activation
To activate the delay feature, perform these steps. (This feature is normally activated at the factory
before shipment.)
1.
Access the Advanced Configuration Group.
2.
Press the SET/NEXT switch down until Topt is displayed.
3.
Note which On/Off indicator light is on. If the red light is on, the delay feature is off. If the green
light is on, the feature is on.
4.
Press SET/NEXT up twice to toggle the delay feature on or off.
When the delay feature is on, the TDLY item is available in the Basic Configuration Group Menu.
4.7.1.2 CM-5RTD Sub-address
With Topt set on (as in previous procedure), perform these steps to set the time delay Subaddress.
This value is the card subaddress for the time delay module incorporated into the CM-5RTD module.
The card subaddress can be set from 1 through 36.
1.
On the basic configuration group, use GROUP to display TDLY.
2.
Press SET/NEXT down to access the delay parameters. TDSA (time delay subaddress) is displayed.
3.
Press SET/NEXT up to select TDSA. The display shows the currently programmed address.
4.
Press SET/NEXT down to begin editing. The underline indicates the digit to be edited.
5.
Press SET/NEXT up to change the first digit.
6.
Press SET/NEXT down to select the second digit; press SET/NEXT up to change its value.
7.
Press SET/NEXT down to enter the value. The red On/Off light is on to indicate that the value is
not yet active.
8.
Press SET/NEXT up twice to confirm and activate the new address.
4.7.1.3 Local Control Set for On or Off
To enable or disable local control of the delay feature, perform these steps:
1.
On the basic function menu use GROUP to display TDLY.
2.
Press SET/NEXT down to access the delay parameters.
3.
Press SET/NEXT down again to display LCL (local).
4.
Note which On/Off indicator light is on. If the green light is on, local control is enabled. If the red
light is on, local control is disabled and the delay feature can only be controlled remotely using
ISiCL commands.
5.
Press SET/NEXT up twice to toggle LCL on or off.
4.7.2
Operation
The CM-5RTD module has a set of indicator lights (Table 4-10) located behind the TIMING indicators.
Содержание ACS-163
Страница 4: ...This page is left blank intentionally...
Страница 12: ...No header here viii Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 52: ...No header 2 30 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 98: ...No header here 4 24 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 144: ...No header 5 46 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 166: ...No header 6 22 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 172: ...No header 7 6 Harris Corporation Intraplex Products This page is left blank intentionally...